MITICA is a negative-Ion-based 1 MeV Neutral Beam Injector. The transverse magnetic field in the plasma source and in the accelerator are crucial for preventing the electrons in the plasma source from entering the accelerator and deflecting the secondary electrons, generated inside the accelerator by stripping reactions with background gas, before they are accelerated at higher energy. The scientific objective of MITICA is essentially the experimental validation of the ITER 1 MeV Neutral Beam injector design and indeed a flexible solution is necessary in order to allow an independent variation of the magnetic field in the plasma source and in the accelerator during the experimental campaign. To this purpose a specific magnetic design has been developed and optimized, essentially based on current-carrying busbars with the possible addition of external coils or magnets. The validated magnetic field configuration will then be replicated in the ITER HNB, using only a current-carrying busbar system. The paper presents the rationale of the various steps of this process and the final design obtained.

Flexible Magnetic Design of the MITICA Plasma Source and Accelerator

Agostinetti P;Serianni G;
2013

Abstract

MITICA is a negative-Ion-based 1 MeV Neutral Beam Injector. The transverse magnetic field in the plasma source and in the accelerator are crucial for preventing the electrons in the plasma source from entering the accelerator and deflecting the secondary electrons, generated inside the accelerator by stripping reactions with background gas, before they are accelerated at higher energy. The scientific objective of MITICA is essentially the experimental validation of the ITER 1 MeV Neutral Beam injector design and indeed a flexible solution is necessary in order to allow an independent variation of the magnetic field in the plasma source and in the accelerator during the experimental campaign. To this purpose a specific magnetic design has been developed and optimized, essentially based on current-carrying busbars with the possible addition of external coils or magnets. The validated magnetic field configuration will then be replicated in the ITER HNB, using only a current-carrying busbar system. The paper presents the rationale of the various steps of this process and the final design obtained.
2013
Istituto gas ionizzati - IGI - Sede Padova
Inglese
AIP Conference Proceedings - THIRD INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES (NIBS 2012)
3rd International Symposium on Negative Ions, Beams and Sources, NIBS 2012
217
226
10
978-0-7354-1136-4
http://scitation.aip.org/content/aip/proceeding/aipcp/10.1063/1.4792788
American Institute of Physics
Melville [NY]
STATI UNITI D'AMERICA
Sì, ma tipo non specificato
3-7 September 2012
Jyvaskyla, Finland
Neutral beam injector
Magnetic inverse problem
Simulated Annealing
La rivista è pubblicata anche online con ISSN 1551-7616.
2
none
Chitarin G.; Marconato N.; Agostinetti P.; Serianni G.; Sonato P.
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
   EU Fusion for ITER Applications
   EUFORIA
   FP7
   211804
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/177557
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 10
social impact