Positive pressure ventilation used nowadays extensively to preserve life, to assist inefficient spontaneous breathing or during any kind of surgery, is known to have an adverse effect on cardiovascular system. LVAD is one of the method to assist circulation in pathological conditions. Its application is supposed to increase total cardiac output, systemic arterial pressure (Pas), right atrial pressure (Pra) and decrease natural cardiac output, left atrial pressure (Pla) and pulmonary arterial pressure (Pap). Mechanical ventilation of the lungs causes same side-effects that influence mainly haemodynamics: decrease cardiac output (CO) and systemic aortic pressure but increase systemic venous pressure (Pvs). The aim of the study was to assess the influence of LVAD on haemodynamic parameters when mechanical ventilation of the lungs is applied.

Haemodynamic parameters changes with LVAD and mechanical ventilation.

De Lazzari C;Ferrari G
1997

Abstract

Positive pressure ventilation used nowadays extensively to preserve life, to assist inefficient spontaneous breathing or during any kind of surgery, is known to have an adverse effect on cardiovascular system. LVAD is one of the method to assist circulation in pathological conditions. Its application is supposed to increase total cardiac output, systemic arterial pressure (Pas), right atrial pressure (Pra) and decrease natural cardiac output, left atrial pressure (Pla) and pulmonary arterial pressure (Pap). Mechanical ventilation of the lungs causes same side-effects that influence mainly haemodynamics: decrease cardiac output (CO) and systemic aortic pressure but increase systemic venous pressure (Pvs). The aim of the study was to assess the influence of LVAD on haemodynamic parameters when mechanical ventilation of the lungs is applied.
1997
Inglese
Rabischong P., Melin J., Naleçz M.
4th European Conference on Engineering and Medicine: Books of Abstracts
4th European Conference on Engineering and Medicine
352
Sì, ma tipo non specificato
25-28 May
Warsaw
Left ventricular assist device
Haemodynamic
Mechanical ventilation
3
info:eu-repo/semantics/conferenceObject
none
274
04 Contributo in convegno::04.02 Abstract in Atti di convegno
De Lazzari, C; Darowski, M; Ferrari, G
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/178201
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact