The JET gamma-ray diagnostics system provides information on the behaviour of fast particles within the tokamak plasma. Information on the spatial distribution of the interacting fast particles is obtained from the gamma-ray cameras, while energy distribution information is provided by gamma-ray spectrometers. These techniques have been successfully applied so far in fast particle simulation experiments at JET. The extension of these diagnostics to high performance discharges with high neutron yields is not straightforward due to the background gamma-ray emission induced by neutrons. Two gamma-ray diagnostics upgrade projects at JET addressed this issue by developing neutron/gamma radiation filters ("neutron attenuators") and collimators for a proper definition of the radiation (neutron and gamma) fields along the diagnostics line-of-sight. A pair of neutron/gamma collimators working in a tandem configuration have been designed and constructed for the JET quasi-tangential gamma-ray spectrometer. The tandem collimators were designed to provide shielding factors of about 5 × 10E2 for 2.45 MeV neutrons and about 10E3 for 9 MeV gamma-rays. The devices have been installed on the JET machine and the paper presents the first experimental results. A similar tandem collimator system was designed for deuterium-tritium experiments on JET. The results of neutron-photon transport calculations for 14.1 MeV neutrons are also presented.

Definition of the radiation fields for the JET gamma-ray spectrometer diagnostics

Andrea Murari;
2013

Abstract

The JET gamma-ray diagnostics system provides information on the behaviour of fast particles within the tokamak plasma. Information on the spatial distribution of the interacting fast particles is obtained from the gamma-ray cameras, while energy distribution information is provided by gamma-ray spectrometers. These techniques have been successfully applied so far in fast particle simulation experiments at JET. The extension of these diagnostics to high performance discharges with high neutron yields is not straightforward due to the background gamma-ray emission induced by neutrons. Two gamma-ray diagnostics upgrade projects at JET addressed this issue by developing neutron/gamma radiation filters ("neutron attenuators") and collimators for a proper definition of the radiation (neutron and gamma) fields along the diagnostics line-of-sight. A pair of neutron/gamma collimators working in a tandem configuration have been designed and constructed for the JET quasi-tangential gamma-ray spectrometer. The tandem collimators were designed to provide shielding factors of about 5 × 10E2 for 2.45 MeV neutrons and about 10E3 for 9 MeV gamma-rays. The devices have been installed on the JET machine and the paper presents the first experimental results. A similar tandem collimator system was designed for deuterium-tritium experiments on JET. The results of neutron-photon transport calculations for 14.1 MeV neutrons are also presented.
2013
Istituto gas ionizzati - IGI - Sede Padova
Inglese
88
6-8
1366
1370
5
http://www.sciencedirect.com/science/article/pii/S0920379613000938
Sì, ma tipo non specificato
Tokamak
Diagnostics
Gamma-rays
Neutrons
Gamma-ray spectrometers
This work was supported by EURATOM and carried out within the framework of the European Fusion Development Agreement. "Funding under Association Contract FU07-CT-2007-00053". / Available online 17 February 2013, E-ISSN 1873-7196. Proceedings of the 27th Symposium On Fusion Technology (SOFT-27); Liège, Belgium, September 24-28, 2012.
11
info:eu-repo/semantics/article
262
Zoita, Vasile; Soare, Sorin; Craciunescu, Teddy; Curuia, Marian; Kiptily, Vasily; Balshaw, Nick; Blanchard, Patrick; Croft, David; Murari, Andrea; Sym...espandi
01 Contributo su Rivista::01.01 Articolo in rivista
none
   EU Fusion for ITER Applications
   EUFORIA
   FP7
   211804
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/180571
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact