The work explores the feasibility of high resolution (as fine as 0.02 cm-1) Fourier transform spectroscopy applied at 9 K in the 500-25000 cm-1 range to detect traces of unwanted impurities, mainly rare earths (RE3+)in crystals: the system chosen is YAl3(BO3)4 (YAB). Weak traces of RE3+ (Nd, Dy, Er, Tm, Yb), but also of Cr3+ and OH-, were successfully monitored by comparing the spectra of YAB samples under examination with those intentionally doped with a given ion. The analysis performed on a variety of samples shows how Cr3+, Nd3+, and Yb3+ are the most frequent unwanted dopants and can provide suggestions to the crystal growers about the performances of different crystal growth lines. According to a preliminary evaluation, the Er3+ traces detection limit is as low as 1-2×10-4 mol% in 1 cm thick samples. The advantages of the method, which is sample non-destructive, are discussed in comparison with those currently applied.

High resolution spectroscopy to investigate impurity traces in YAB single crystals

Buffagni;Elisa;
2011

Abstract

The work explores the feasibility of high resolution (as fine as 0.02 cm-1) Fourier transform spectroscopy applied at 9 K in the 500-25000 cm-1 range to detect traces of unwanted impurities, mainly rare earths (RE3+)in crystals: the system chosen is YAl3(BO3)4 (YAB). Weak traces of RE3+ (Nd, Dy, Er, Tm, Yb), but also of Cr3+ and OH-, were successfully monitored by comparing the spectra of YAB samples under examination with those intentionally doped with a given ion. The analysis performed on a variety of samples shows how Cr3+, Nd3+, and Yb3+ are the most frequent unwanted dopants and can provide suggestions to the crystal growers about the performances of different crystal growth lines. According to a preliminary evaluation, the Er3+ traces detection limit is as low as 1-2×10-4 mol% in 1 cm thick samples. The advantages of the method, which is sample non-destructive, are discussed in comparison with those currently applied.
2011
Istituto dei Materiali per l'Elettronica ed il Magnetismo - IMEM
Inglese
46
8
755
760
6
http://onlinelibrary.wiley.com/doi/10.1002/crat.201000619/abstract;jsessionid=C31BBD9355A901D80A34DD44761BF388.d02t02
Sì, ma tipo non specificato
high resolution spectroscopy
impurity detection
lanthanides
Special Issue: Italien Crystal Growth Conference 2010 (ICG2010) ID_PUMA: cnr.imem/2011-A0-037
1
info:eu-repo/semantics/article
262
Mazzera; Margherita ; Baraldi; Andrea ; Buffagni; Elisa ; Capelletti; Rosanna ; Földvári; Istvan
01 Contributo su Rivista::01.01 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/182727
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 0
social impact