The measurement of the thermal inertia of moist porous materials by active thermal monitoring is analyzed. Various solutions of the heat-conduction problem are investigated, and the assumptions introduced to simplify data collection are discussed. An error analysis is carried out, providing a means for optimizing the chosen testing method.

ACTIVE THERMAL MONITORING OF THE MOISTURE-CONTENT OF POROUS MATERIALS

E GRINZATO;S MARINETTI;
1994

Abstract

The measurement of the thermal inertia of moist porous materials by active thermal monitoring is analyzed. Various solutions of the heat-conduction problem are investigated, and the assumptions introduced to simplify data collection are discussed. An error analysis is carried out, providing a means for optimizing the chosen testing method.
1994
Istituto per le Tecnologie della Costruzione - ITC
File in questo prodotto: