A thermal imaging system has been installed on the RFX at Consorzio RFX to investigate the phenomenology of the plasma wall interactions. The infrared camera, model Amber AE4128, is based on a 128×128 InSb focal plane array detector and operates in the range of 4.5-5 ?m with an acquisition rate of 217 Hz and 12 bit of dynamic range. The system, absolutely calibrated, is sensitive from room temperature up to 3000 °C, with different setups. The experimental data are compared with the numerical results obtained by means of transient thermal analyses carried out on analytical and finite element models of a graphite tile.
System for temperature and power flux measurements on the RFX first wall
RPasqualotto;MValisa;
1999
Abstract
A thermal imaging system has been installed on the RFX at Consorzio RFX to investigate the phenomenology of the plasma wall interactions. The infrared camera, model Amber AE4128, is based on a 128×128 InSb focal plane array detector and operates in the range of 4.5-5 ?m with an acquisition rate of 217 Hz and 12 bit of dynamic range. The system, absolutely calibrated, is sensitive from room temperature up to 3000 °C, with different setups. The experimental data are compared with the numerical results obtained by means of transient thermal analyses carried out on analytical and finite element models of a graphite tile.| File | Dimensione | Formato | |
|---|---|---|---|
|
prod_253211-doc_82111.pdf
solo utenti autorizzati
Descrizione: System for temperature and power flux measurements on the RFX first wall
Dimensione
418.79 kB
Formato
Adobe PDF
|
418.79 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |