Matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) allows detection of large molecules such as those present in synthetic and natural macromolecules. Until recently, it was reported that MALDI-TOF measurements can provide correct molecular weight (MW) averages only for samples with a narrow MW distribution (M,IM,, I 1.20). We have now developed a methodology for polydisperse samples. We recorded the GPC trace of two polydisperse polymeric samples, namely, poly(buty1ene adipate) (PBA) and poly(buty1ene adipate-co-butylene succinate) (PBAS), collecting about 40-50 fractions per run. Selected fractions were analyzed by MALDI-TOF, and the average MW of each fraction was determined, allowing calibration of the GPC curves against absolute MW. The two calibrated GPC traces were then used to compute average MW and molecular weight distributions (MWD) of the unfractionated samples. End group analysis from MALDI-TOF spectra revealed that the PBA sample is composed of seven different types of chains. For the copolymer sample, PBAS, analysis of the MALDI spectra established a random sequence distribution of comonomer units. The succinateladipate molar ratio calculated from the MALDI spectra is in good agreement with the molar ratio found by NMR.

MOLECULAR AND STRUCTURAL CHARACTERIZATION OF POLYDISPERSE POLYMERS AND COPOLYMERS BY COMBINING MALDI-TOF MASS-SPECTROMETRY WITH GPC FRACTIONATION

Filippo Samperi
1995

Abstract

Matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) allows detection of large molecules such as those present in synthetic and natural macromolecules. Until recently, it was reported that MALDI-TOF measurements can provide correct molecular weight (MW) averages only for samples with a narrow MW distribution (M,IM,, I 1.20). We have now developed a methodology for polydisperse samples. We recorded the GPC trace of two polydisperse polymeric samples, namely, poly(buty1ene adipate) (PBA) and poly(buty1ene adipate-co-butylene succinate) (PBAS), collecting about 40-50 fractions per run. Selected fractions were analyzed by MALDI-TOF, and the average MW of each fraction was determined, allowing calibration of the GPC curves against absolute MW. The two calibrated GPC traces were then used to compute average MW and molecular weight distributions (MWD) of the unfractionated samples. End group analysis from MALDI-TOF spectra revealed that the PBA sample is composed of seven different types of chains. For the copolymer sample, PBAS, analysis of the MALDI spectra established a random sequence distribution of comonomer units. The succinateladipate molar ratio calculated from the MALDI spectra is in good agreement with the molar ratio found by NMR.
1995
CHIMICA E TECNOLOGIA DEI POLIMERI
Istituto per i Polimeri, Compositi e Biomateriali - IPCB
Inglese
28
24
7983
7989
7
Sì, ma tipo non specificato
MASS Spectrometry
GPC
Copolymer
Characterization
3
info:eu-repo/semantics/article
262
Montaudo, Giorgio; S Montaudo Concetto Puglisi, Domenico Garozzo Maurizio; Samperi, Filippo
01 Contributo su Rivista::01.01 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/193470
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact