We used Stycast 1266 in a high-pressure, low-temperature transducer. In order to ascertain the dependence of capacitance and loss on temperature, we measured the temperature behaviour of the dielectric constant and the dissipation factor of Stycast 1266 at 1 {KHz} between 0.07 and 300 K. We found a smooth decrease of the dielectric constant with decreasing T. The temperature dependence below 1 K is well explained by the tunneling model. The loss tangent showed very low values (always less than 5×10-5), with a peak around 260 K that can be ascribed to dielectric relaxation processes.

Dielectric properties of Stycast 1266 over the 0.07-300 K temperature range

M Barucci;G Bianchini;
1999

Abstract

We used Stycast 1266 in a high-pressure, low-temperature transducer. In order to ascertain the dependence of capacitance and loss on temperature, we measured the temperature behaviour of the dielectric constant and the dissipation factor of Stycast 1266 at 1 {KHz} between 0.07 and 300 K. We found a smooth decrease of the dielectric constant with decreasing T. The temperature dependence below 1 K is well explained by the tunneling model. The loss tangent showed very low values (always less than 5×10-5), with a peak around 260 K that can be ascribed to dielectric relaxation processes.
1999
Inglese
39
11
963
966
http://www.sciencedirect.com/science/article/pii/S0011227599001307
Sì, ma tipo non specificato
1
info:eu-repo/semantics/article
262
M. Barucci ; G. Bianchini ; E. Gottardi ; I. Peroni ;G Ventura
01 Contributo su Rivista::01.01 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/200453
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 11
social impact