In this work a modification process is described, which is used to restore density maps of anatomic cross-sections obtained by means of a ?-camera. Density maps are obtained with the aid of a ?-ray linear source which irradiates the chest of patients under rest: radiations which are orthogonally diffracted by Compton scattering are detected by a large-field ?-camera with a planar collimator parallel to the primary beam direction. Patterns formed on the camera CRT are photographed and digitized and the resulting matrices are then processed with a digital computer in order to restore the actual density of scanned tissues. Pixels of Compton scattering images are badly affected by several distortions. Some partially interactive restoring algorithms are executed in order to reduce noise and distortion.

Chest tomography by compton scattered radiation: a heuristic enhancement and restoration

Chimenti M;Fabbrini F
1980

Abstract

In this work a modification process is described, which is used to restore density maps of anatomic cross-sections obtained by means of a ?-camera. Density maps are obtained with the aid of a ?-ray linear source which irradiates the chest of patients under rest: radiations which are orthogonally diffracted by Compton scattering are detected by a large-field ?-camera with a planar collimator parallel to the primary beam direction. Patterns formed on the camera CRT are photographed and digitized and the resulting matrices are then processed with a digital computer in order to restore the actual density of scanned tissues. Pixels of Compton scattering images are badly affected by several distortions. Some partially interactive restoring algorithms are executed in order to reduce noise and distortion.
1980
Istituto di Scienza e Tecnologie dell'Informazione "Alessandro Faedo" - ISTI
Chest tomography
Compton scattered radiation
File in questo prodotto:
File Dimensione Formato  
prod_239145-doc_151121.pdf

solo utenti autorizzati

Descrizione: Chest tomography by compton scattered radiation: a heuristic enhancement and restoration
Tipologia: Versione Editoriale (PDF)
Dimensione 2.16 MB
Formato Adobe PDF
2.16 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/204160
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact