Objectives. The aim of this study was to explore the possibility of quantifying coronary blood flow by myocardial contrast echocardiography with air-filled serum albumin microspheres (Albunex). Background. Air-filled albumin microspheres have been proposed as an intravascular tracer for the study of myocardial perfusion by contrast echocardiography. Methods. In six anesthetized open chest dogs, the left circumflex coronary artery was cannulated and perfused by a roller pump with blood from the femoral artery. Both air-filled albumin microspheres (0.4 ml, 2 × 108 spheres/ml) and technetium-99m-labeled albumin were injected as a bolus into the coronary cannula at baseline and after treatment with dipyridamole (0.56 mg/kg body weight intravenously for 4 min). Two-dimensional echographic images of the left ventricular short axis were digitized to generate myocardial time-intensity curves; myocardial radioactivity was measured by an external detector to generate radionuclide time-activity curves. Results. After dipyridamole, left circumflex coronary artery blood flow (as measured by both the pump and an electromagnetic flow meter) significantly increased (from 1.06 ± 0.28 to 3.61 ± 1.43 ml/min per g of myocardium). Peak intensity and rise time of contrast echo curves were able to differentiate baseline myocardial perfusion from coronary hyperemia but did not show any significant correlation with coronary blood flow. A weak inverse correlation with coronary blood flow was provided by myocardial mean transit time of air-filled albumin microspheres (r = 0.33). Conversely, a close inverse correlation with coronary blood flow was obtained by myocardial mean transit time of technetium-99m-labeled albumin (r = 0.95). Myocardial transit time of air-filled albumin microspheres (1.95 ± 0.60 s) was also markedly shorter than that of labeled albumin (5.35 ± 3.43 s, p < 0.001) and the measurements were less reproducible. Conclusions. In this experimental study, coronary blood flow was not adequately quantified by myocardial contrast echocardiography with intracoronary injection of air-filled albumin microspheres.

Intracoronary air-filled albumin microspheres for myocardial blood flow measurement

Daniele Rovai;Maria Giovanna Trivella;
1993

Abstract

Objectives. The aim of this study was to explore the possibility of quantifying coronary blood flow by myocardial contrast echocardiography with air-filled serum albumin microspheres (Albunex). Background. Air-filled albumin microspheres have been proposed as an intravascular tracer for the study of myocardial perfusion by contrast echocardiography. Methods. In six anesthetized open chest dogs, the left circumflex coronary artery was cannulated and perfused by a roller pump with blood from the femoral artery. Both air-filled albumin microspheres (0.4 ml, 2 × 108 spheres/ml) and technetium-99m-labeled albumin were injected as a bolus into the coronary cannula at baseline and after treatment with dipyridamole (0.56 mg/kg body weight intravenously for 4 min). Two-dimensional echographic images of the left ventricular short axis were digitized to generate myocardial time-intensity curves; myocardial radioactivity was measured by an external detector to generate radionuclide time-activity curves. Results. After dipyridamole, left circumflex coronary artery blood flow (as measured by both the pump and an electromagnetic flow meter) significantly increased (from 1.06 ± 0.28 to 3.61 ± 1.43 ml/min per g of myocardium). Peak intensity and rise time of contrast echo curves were able to differentiate baseline myocardial perfusion from coronary hyperemia but did not show any significant correlation with coronary blood flow. A weak inverse correlation with coronary blood flow was provided by myocardial mean transit time of air-filled albumin microspheres (r = 0.33). Conversely, a close inverse correlation with coronary blood flow was obtained by myocardial mean transit time of technetium-99m-labeled albumin (r = 0.95). Myocardial transit time of air-filled albumin microspheres (1.95 ± 0.60 s) was also markedly shorter than that of labeled albumin (5.35 ± 3.43 s, p < 0.001) and the measurements were less reproducible. Conclusions. In this experimental study, coronary blood flow was not adequately quantified by myocardial contrast echocardiography with intracoronary injection of air-filled albumin microspheres.
1993
Istituto di Fisiologia Clinica - IFC
Myocardial Perfusion
echocardiography
contrast media
File in questo prodotto:
File Dimensione Formato  
prod_249138-doc_66249.pdf

accesso aperto

Descrizione: Intracoronary air-filled albumin microspheres for myocardial blood flow measurement
Dimensione 2.03 MB
Formato Adobe PDF
2.03 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/205417
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact