Background: To evaluate whether Contrast Enhanced Ultrasund (CEUS) with microbubbles (MBs) targeted to VEGFR-2 is able to characterize in vivo the VEGFR-2 expression in the tumor vasculature of a mouse model of thyroid cancer (Tg-TRK-T1). Methods: Animal protocol was approved by Institutional committee on Laboratory Animal Care. Contrast-enhanced ultrasound imaging with MBs targeted with an anti-VEGFR-2 monoclonal antibody (UCAVEGFR-2) and isotype control antibody (UCAIgG) was performed in 7 mice with thyroid carcinoma, 5 mice with hyperplasia or benign thyroid nodules and 4 mice with normal thyroid. After ultrasonography, the tumor samples were harvested for histological examination and VEGFR-2 expression was tested by immunohistochemistry. Data were reported as median and range. Paired non parametric Wilcoxon's test and ANOVA of Kruskal-Wallis were used. The correlation between the contrast signal and the VEGFR-2 expression was assessed by the Spearman coefficient. Results: The Video intensity difference (VID) caused by backscatter of the retained UCAVEGFR-2 was significantly higher in mice harboring thyroid tumors compared to mice with normal thyroids (P < 0.01) and to mice harboring benign nodules (P < 0.01). No statistically significant differences of VID were observed in the group of mice carrying benign nodules compared to mice with normal thyroids. Moreover in thyroid tumors VID of retained VEGFR-2-targeted UCA was significantly higher than that of control UCAIgG (P <0.05). Results of immunohistochemical analysis confirmed VEGFR-2 overexpression. The magnitude of the molecular ultrasonographic signal from a VEGFR-2-targeted UCA retained by tissue correlates with VEGFR-2 expression determined by immunohistochemistry (rho 0.793, P=0.0003). Conclusions: We demonstrated that CEUS with UCAVEGFR-2 might be used for in vivo non invasive detection and quantification of VEGFR-2 expression in thyroid cancer in mice, and to differentiate benign from malignant thyroid nodules

Imaging of thyroid tumor angiogenesis with microbubbles targeted to vascular endothelial growth factor receptor type 2 in mice

Mancini M;Liuzzi R;
2013-01-01

Abstract

Background: To evaluate whether Contrast Enhanced Ultrasund (CEUS) with microbubbles (MBs) targeted to VEGFR-2 is able to characterize in vivo the VEGFR-2 expression in the tumor vasculature of a mouse model of thyroid cancer (Tg-TRK-T1). Methods: Animal protocol was approved by Institutional committee on Laboratory Animal Care. Contrast-enhanced ultrasound imaging with MBs targeted with an anti-VEGFR-2 monoclonal antibody (UCAVEGFR-2) and isotype control antibody (UCAIgG) was performed in 7 mice with thyroid carcinoma, 5 mice with hyperplasia or benign thyroid nodules and 4 mice with normal thyroid. After ultrasonography, the tumor samples were harvested for histological examination and VEGFR-2 expression was tested by immunohistochemistry. Data were reported as median and range. Paired non parametric Wilcoxon's test and ANOVA of Kruskal-Wallis were used. The correlation between the contrast signal and the VEGFR-2 expression was assessed by the Spearman coefficient. Results: The Video intensity difference (VID) caused by backscatter of the retained UCAVEGFR-2 was significantly higher in mice harboring thyroid tumors compared to mice with normal thyroids (P < 0.01) and to mice harboring benign nodules (P < 0.01). No statistically significant differences of VID were observed in the group of mice carrying benign nodules compared to mice with normal thyroids. Moreover in thyroid tumors VID of retained VEGFR-2-targeted UCA was significantly higher than that of control UCAIgG (P <0.05). Results of immunohistochemical analysis confirmed VEGFR-2 overexpression. The magnitude of the molecular ultrasonographic signal from a VEGFR-2-targeted UCA retained by tissue correlates with VEGFR-2 expression determined by immunohistochemistry (rho 0.793, P=0.0003). Conclusions: We demonstrated that CEUS with UCAVEGFR-2 might be used for in vivo non invasive detection and quantification of VEGFR-2 expression in thyroid cancer in mice, and to differentiate benign from malignant thyroid nodules
2013
Istituto di Biostrutture e Bioimmagini - IBB - Sede Napoli
Cancer
Contrast agent
High resolution ultrasound
Thyroid
Transgenic
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/208966
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? ND
social impact