In this paper the frequency response of two CTs is experimentally evaluated in the range of 30-600 Hz. A theoretical analysis of CTs behavior has been developed by means of the equivalent circuit. It was shown, by an experimental test, that, for the frequency range analyzed, the transformer equivalent circuit is a valid tool for the evaluation of CT performances. ©2008 IEEE.

Frequency response of measurement current transformers

Di Cara D;
2008

Abstract

In this paper the frequency response of two CTs is experimentally evaluated in the range of 30-600 Hz. A theoretical analysis of CTs behavior has been developed by means of the equivalent circuit. It was shown, by an experimental test, that, for the frequency range analyzed, the transformer equivalent circuit is a valid tool for the evaluation of CT performances. ©2008 IEEE.
2008
9781424415410
Computer networks
Electric instrument transformers
Electric network analysis
Instruments
Measurement theory
Current transformer
Harmonic distortion
Measurement technologies
Power system harmo
Transducers
Frequency response
File in questo prodotto: