Gas Electron Multiplier based detectors have been recently used for neutron measurement at spallation sources and for fusion relevant applications. The present work is meant to characterize the detector sensitivity to gamma-ray background which often can represent the main background source associated to neutron measurements. The gamma-ray sensitivity has been measured as a function of detector gain and it has been found to be lower than 10(-7) at the typical gain used for neutrons detection. Coincidence measurements, giving the possibility to select mono-energetic photons and to suppress background events, allowed to measure the absolute sensitivity at a well defined gamma-ray energy and at low interaction rates. The mechanism of interaction and energy deposition of gamma-rays in the detector has been studied using MCNPX Monte Carlo simulations.

Measurements of gamma-ray sensitivity of a GEM based detector using a coincidence technique

Croci G;Tardocchi M;Grosso G;Gorini G
2013

Abstract

Gas Electron Multiplier based detectors have been recently used for neutron measurement at spallation sources and for fusion relevant applications. The present work is meant to characterize the detector sensitivity to gamma-ray background which often can represent the main background source associated to neutron measurements. The gamma-ray sensitivity has been measured as a function of detector gain and it has been found to be lower than 10(-7) at the typical gain used for neutrons detection. Coincidence measurements, giving the possibility to select mono-energetic photons and to suppress background events, allowed to measure the absolute sensitivity at a well defined gamma-ray energy and at low interaction rates. The mechanism of interaction and energy deposition of gamma-rays in the detector has been studied using MCNPX Monte Carlo simulations.
2013
Istituto di fisica del plasma - IFP - Sede Milano
Interaction of radiation with matter
Micropattern gaseous detectors
MSGC
GEM
THGEM
RETHGEM
MHSP
MICROPIC
MICROMEGAS
InGrid
Neutron detectors
cold thermal
fast neutrons
File in questo prodotto:
File Dimensione Formato  
prod_269162-doc_74886.pdf

solo utenti autorizzati

Descrizione: Articolo
Tipologia: Versione Editoriale (PDF)
Dimensione 792.24 kB
Formato Adobe PDF
792.24 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/209751
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 26
social impact