The realisation process and the preliminary tests on the performances of an integrated Mach-Zehnder Interferometer on LiNbO3 (Lithium Niobate) substrate is presented. The microsystem has been obtained by using medium mass Ion Implantation on X-cut Lithium Niobate crystals. The interferometer is formed by integrated optical channel waveguides; the phase shift between the two optical paths has been obtained, without moving parts. by applying a suitable electric field. The whole device is 60mm long, has a O.5xlmm2 cross section and weights a few grams. The power consumption is in the milliwatt range. In the present work results obtained in the spectral window (O.4jim-l .Iim) will be presented. The performance of the device, evaluated on standard radiation sources, demonstrates that a spectral resolution better than O.3nm can be obtained on 400nm spectral windows. The Micro-interferometer has been tested in laboratory with a calibrated cell containing NO2 gas and has demonstrated sensitivity in the ppb range if suitable optical paths are used. Its reduced dimensions and weights make these micro-systems ideal for a wide range of applications, spanning from Space Technology, Earth observation for Environmentmonitoring, to Safety and Security applications.

Integrated Mach-Zehnder micro-interferometer for gas trace remote sensing

G G Bentini;M Bianconi;
2006

Abstract

The realisation process and the preliminary tests on the performances of an integrated Mach-Zehnder Interferometer on LiNbO3 (Lithium Niobate) substrate is presented. The microsystem has been obtained by using medium mass Ion Implantation on X-cut Lithium Niobate crystals. The interferometer is formed by integrated optical channel waveguides; the phase shift between the two optical paths has been obtained, without moving parts. by applying a suitable electric field. The whole device is 60mm long, has a O.5xlmm2 cross section and weights a few grams. The power consumption is in the milliwatt range. In the present work results obtained in the spectral window (O.4jim-l .Iim) will be presented. The performance of the device, evaluated on standard radiation sources, demonstrates that a spectral resolution better than O.3nm can be obtained on 400nm spectral windows. The Micro-interferometer has been tested in laboratory with a calibrated cell containing NO2 gas and has demonstrated sensitivity in the ppb range if suitable optical paths are used. Its reduced dimensions and weights make these micro-systems ideal for a wide range of applications, spanning from Space Technology, Earth observation for Environmentmonitoring, to Safety and Security applications.
2006
Jingshan Jiang, O. Yu. Nosach, Jiaqi Wang
Remote Sensing and Infrared Devices and Systems
ICO20: Remote Sensing and Infrared Devices and Systems
603106-1
603106-5
Sì, ma tipo non specificato
9
none
Chiarini, M; G Bentini, G; Bianconi, M; Cerutti, A; Pennestrì, G; Wang, Pengfei; She, Lin; Mazzoldi, P; Sada, C
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/213528
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact