The purpose of this study was to acquire a new correction factor for use in tracer estimations of plasma fatty acid oxidation that would fully account for label fixation during the infusion of fatty acid tracers. Thus volunteers were infused with 13C-labeled fatty acids and [1-14C]acetate in the basal state, during hyperinsulinemia-hyperglycemia (clamp), and during 1 h of cycling exercise. The fractional recovery of acetate label (i.e., the acetate correction factor) was 0.56 +/- 0.02, 0.50 +/- 0.03, and 0.80 +/- 0.03 in the basal state and during the clamp and exercise, respectively. Isotopically determined plasma fatty acid oxidation rates (mumol.kg-1.min-1) were 1.7 +/- 0.2, 0.8 +/- 0.2, and 6.4 +/- 0.5 (no correction); 2.1 +/- 0.2, 1.0 +/- 0.2, and 6.7 +/- 0.5 (bicarbonate correction); and 3.1 +/- 0.2, 1.5 +/- 0.2, and 8.2 +/- 0.4 (acetate correction). We conclude that use of the acetate correction factor in place of the bicarbonate correction factor should improve the accuracy of isotopic measurements of plasma fatty acid oxidation, because it accounts for label fixation that might occur at any step between the entrance of labeled acetyl-CoA into the tricarboxylic acid cycle until the recovery of label in breath CO2.

A New Correction Factor for Use in Tracer Estimations of Plasma Fatty-Acid Oxidation

Gastaldelli A;
1995

Abstract

The purpose of this study was to acquire a new correction factor for use in tracer estimations of plasma fatty acid oxidation that would fully account for label fixation during the infusion of fatty acid tracers. Thus volunteers were infused with 13C-labeled fatty acids and [1-14C]acetate in the basal state, during hyperinsulinemia-hyperglycemia (clamp), and during 1 h of cycling exercise. The fractional recovery of acetate label (i.e., the acetate correction factor) was 0.56 +/- 0.02, 0.50 +/- 0.03, and 0.80 +/- 0.03 in the basal state and during the clamp and exercise, respectively. Isotopically determined plasma fatty acid oxidation rates (mumol.kg-1.min-1) were 1.7 +/- 0.2, 0.8 +/- 0.2, and 6.4 +/- 0.5 (no correction); 2.1 +/- 0.2, 1.0 +/- 0.2, and 6.7 +/- 0.5 (bicarbonate correction); and 3.1 +/- 0.2, 1.5 +/- 0.2, and 8.2 +/- 0.4 (acetate correction). We conclude that use of the acetate correction factor in place of the bicarbonate correction factor should improve the accuracy of isotopic measurements of plasma fatty acid oxidation, because it accounts for label fixation that might occur at any step between the entrance of labeled acetyl-CoA into the tricarboxylic acid cycle until the recovery of label in breath CO2.
1995
Istituto di Fisiologia Clinica - IFC
EXERCISE
ISOTOPES
TRICARBOXYLIC ACID CYCLE
INSULIN
SUBSTRATE OXIDATION
File in questo prodotto:
File Dimensione Formato  
prod_212607-doc_61932.pdf

non disponibili

Descrizione: A new correction factor for use in tracer estimations of plasma fatty acid oxidation
Dimensione 2.74 MB
Formato Adobe PDF
2.74 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/215794
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 181
  • ???jsp.display-item.citation.isi??? 178
social impact