Intensity-stabilized laser absorption spectroscopy, in the near-infrared, represents an extremely powerful tool for primary gas thermometry, provided that an accurate procedure of frequency calibration is used. The method consists in retrieving the Doppler width from highly accurate observations of the shape of a spectral line in any atomic or molecular system in the gas phase, at the thermodynamic equilibrium. Applied to CO2 samples in the 2-mu m wavelength region, it has recently allowed to perform a spectroscopic determination of the Boltzmann constant with a relative accuracy of 1.6 x 10(-4). We here discuss the main factors, of both fundamental and technical nature, limiting the accuracy of this method and report on the possibility of approaching the target accuracy of 10(-6) by changing the molecular sample, the operation wavelength and the frequency calibration technique. To cite this article: A. Castrillo et al., C. R. Physique 10 (2009). (C) 2009 Academie des sciences. Published by Elsevier Masson SAS. All fights reserved.

On the determination of the Boltzmann constant by means of precision molecular spectroscopy in the near-infrared

Galzerano;Gianluca;
2009

Abstract

Intensity-stabilized laser absorption spectroscopy, in the near-infrared, represents an extremely powerful tool for primary gas thermometry, provided that an accurate procedure of frequency calibration is used. The method consists in retrieving the Doppler width from highly accurate observations of the shape of a spectral line in any atomic or molecular system in the gas phase, at the thermodynamic equilibrium. Applied to CO2 samples in the 2-mu m wavelength region, it has recently allowed to perform a spectroscopic determination of the Boltzmann constant with a relative accuracy of 1.6 x 10(-4). We here discuss the main factors, of both fundamental and technical nature, limiting the accuracy of this method and report on the possibility of approaching the target accuracy of 10(-6) by changing the molecular sample, the operation wavelength and the frequency calibration technique. To cite this article: A. Castrillo et al., C. R. Physique 10 (2009). (C) 2009 Academie des sciences. Published by Elsevier Masson SAS. All fights reserved.
2009
Istituto di fotonica e nanotecnologie - IFN
Laser spectroscopy
Spectral line shapes
Determination of fundamental constants
SPECTRAL-LINE SHAPES
MU-M
DIODE-LASER
DOPPLER
TEMPERATURE
PARAMETERS
(H2O)-O-18
PRESSURE
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/216011
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 37
social impact