The study of the interaction between a pneumatic left ventricle assist device (LVAD), driven with different control strategies, and the cardiovascular system is the subject of this paper. It is performed by a modular numerical model of the cardiovascular system connected to a numerical model of the LVAD. The circulatory system is simulated by a lumped parameter numerical model. The ventricle is represented by a time-varying elastance model to reproduce the Starling law of the heart. The effect of the LVAD on the cardiovascular system is evaluated, on the left ventricle alone, by an open-loop circuit consisting of the models of the ventricle, the LVAD and the arterial tree. The analysis is performed in terms of energy variables (such as external work and oxygen consumption and cardiac mechanical efficiency versus control strategy. The LVAD is driven by different control strategies: a fixed heart rate (with different delays from the onset of the natural ventricle contraction) and a variable heart rate.

A desk top computer model of the circulatory system for heart assistance simulation: effect of an LVAD on energetic relationships inside the left ventricle.

De Lazzari C;Ferrari G;
1994

Abstract

The study of the interaction between a pneumatic left ventricle assist device (LVAD), driven with different control strategies, and the cardiovascular system is the subject of this paper. It is performed by a modular numerical model of the cardiovascular system connected to a numerical model of the LVAD. The circulatory system is simulated by a lumped parameter numerical model. The ventricle is represented by a time-varying elastance model to reproduce the Starling law of the heart. The effect of the LVAD on the cardiovascular system is evaluated, on the left ventricle alone, by an open-loop circuit consisting of the models of the ventricle, the LVAD and the arterial tree. The analysis is performed in terms of energy variables (such as external work and oxygen consumption and cardiac mechanical efficiency versus control strategy. The LVAD is driven by different control strategies: a fixed heart rate (with different delays from the onset of the natural ventricle contraction) and a variable heart rate.
1994
Istituto di Fisiologia Clinica - IFC
Left ventricular assist device
Ventricular elastance
Haemodynamic
Hert rate
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/216455
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact