A proximity effect correction algorithm requires an accurate knowledge of the energy density function (EDF) deposited in the electron resist layer. In case of high-resolution electron-beam lithography (EBL), whenever the required resolution is below 0.5 ?m, forward and large-angle backward scattering contribution has to be carefully analyzed. In this paper, we compare Monte Carlo (MC) simulation data with experimental point exposure measurements over different substrates and with different beam energy (range 20-40 kV). The substrates we analyze are silicon and silicon nitride membranes (2 ?m thick), indium phosphide, and gold. A good correlation between MC data and experiments is proved. Experiments and MC data suggest that the usual double Gaussian fit applied to the distribution is not suitable for the application of high-resolution lithography or with high-Z materials, These data indicate that the recently proposed triple Gaussian fit can be considered as a particular case of a more complex multi-Gaussian function. Experimental high-resolution resist profiles are then simulated successfully using MC EDFs in a cell development model.

Energy density function determination in a very-high-resolution electron-beam lithography

Lucchesini A;
1990

Abstract

A proximity effect correction algorithm requires an accurate knowledge of the energy density function (EDF) deposited in the electron resist layer. In case of high-resolution electron-beam lithography (EBL), whenever the required resolution is below 0.5 ?m, forward and large-angle backward scattering contribution has to be carefully analyzed. In this paper, we compare Monte Carlo (MC) simulation data with experimental point exposure measurements over different substrates and with different beam energy (range 20-40 kV). The substrates we analyze are silicon and silicon nitride membranes (2 ?m thick), indium phosphide, and gold. A good correlation between MC data and experiments is proved. Experiments and MC data suggest that the usual double Gaussian fit applied to the distribution is not suitable for the application of high-resolution lithography or with high-Z materials, These data indicate that the recently proposed triple Gaussian fit can be considered as a particular case of a more complex multi-Gaussian function. Experimental high-resolution resist profiles are then simulated successfully using MC EDFs in a cell development model.
1990
Istituto Nazionale di Ottica - INO
electron and positron beams
lithography
masks and pattern transfer
electron beam lithography
File in questo prodotto:
File Dimensione Formato  
prod_260387-doc_70887.pdf

solo utenti autorizzati

Descrizione: Reprint of J. of Vac. Sci. Tech. B 8(6), 1867 - 1871 (1990)
Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 667.65 kB
Formato Adobe PDF
667.65 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/216575
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 33
social impact