We describe a technique for determining the boron isotopic composition of low-B silicate rocks which until recently have been difficult to analyze. The method involves an alkali carbonate fusion for sample dissolution, ion-exchange chromatography for boron purification, and PTIMS analysis using Cs2BO+2. Our procedure combines several previously published methods in a unique manner to simultaneously (1) achieve state-of-the-art precision and accuracy, and (2) expedite analysis with respect to competing methods. Because isotopic fractionation corrections typically are based on concurrent analyses of the SRM-951 boric acid reference standard, these data do not provide a true measure of analytical accuracy or interlaboratory biases. In this study, analytical precision and accuracy were evaluated independently through replicate analyses of the JB-2 basalt reference standard, with completely independent chemical extractions of boron in each case. The average corrected ratio obtained is 4.0728 ± 0.0019 (2s external uncertainty), which corresponds to a d11B value of +7.23 ± 0.47?. This result agrees closely with data obtained by Nakamura et al. [Nakamura, E., Ishikawa, T., Birck, J.L., Allègre, C., 1992. Precise boron isotopic analysis of natural rock samples using a boron-mannitol complex. Chem. Geol. 94, 193-204.] using the HF digestion method. We strongly recommend that JB-2 be analyzed routinely in future boron isotopic studies to facilitate assessment of analytical uncertainties and interlaboratory biases.
Precise boron isotopic analysis of complex silicate (rock) samples using alkali carbonate fusion and ion-exchange separation.
Tonarini Sonia;Pennisi Maddalena;
1997
Abstract
We describe a technique for determining the boron isotopic composition of low-B silicate rocks which until recently have been difficult to analyze. The method involves an alkali carbonate fusion for sample dissolution, ion-exchange chromatography for boron purification, and PTIMS analysis using Cs2BO+2. Our procedure combines several previously published methods in a unique manner to simultaneously (1) achieve state-of-the-art precision and accuracy, and (2) expedite analysis with respect to competing methods. Because isotopic fractionation corrections typically are based on concurrent analyses of the SRM-951 boric acid reference standard, these data do not provide a true measure of analytical accuracy or interlaboratory biases. In this study, analytical precision and accuracy were evaluated independently through replicate analyses of the JB-2 basalt reference standard, with completely independent chemical extractions of boron in each case. The average corrected ratio obtained is 4.0728 ± 0.0019 (2s external uncertainty), which corresponds to a d11B value of +7.23 ± 0.47?. This result agrees closely with data obtained by Nakamura et al. [Nakamura, E., Ishikawa, T., Birck, J.L., Allègre, C., 1992. Precise boron isotopic analysis of natural rock samples using a boron-mannitol complex. Chem. Geol. 94, 193-204.] using the HF digestion method. We strongly recommend that JB-2 be analyzed routinely in future boron isotopic studies to facilitate assessment of analytical uncertainties and interlaboratory biases.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.