Characteristics of quasi-single-helicity (QSH) states have been studied in a low-aspect-ratio reversed field pinch (RFP) machine RELAX mainly by magnetic diagnostics. Internal profiles of the fluctuating radial, poloidal and toroidal magnetic fields have shown good agreement with eigenfunctions of a single helical mode. The edge magnetic fluctuation spectra are somewhat broader than what are expected from internal magnetic field profiles. In spite of these slight discrepancies, the usual measure for the QSH, the spectral index NS lower than 2, still provides a reasonable measure for QSH states in RELAX. The QSH persistence has been improved in RELAX by the reduction of the poloidal resistance of flanges at poloidal gaps, mainly due to the improved axisymmetry of the toroidal magnetic field. QSH persistence more than 30% of the flat-topped current phase has been realized with current density lower than in other RFP, and probability of spontaneous QSH is 12.8 ± 7.3% which is higher than high-aspect-ratio RFP. It suggests the advantage of low-aspect-ratio configuration in attaining to the QSH. Comparison with recent experiments using active resonant perturbation may suggest the importance of further reduction of field errors to improve the quality of QSH.

Characterization of Quasi-Single-Helicity States in a Low-Aspect-Ratio RFP

Roberto PACCAGNELLA
2012

Abstract

Characteristics of quasi-single-helicity (QSH) states have been studied in a low-aspect-ratio reversed field pinch (RFP) machine RELAX mainly by magnetic diagnostics. Internal profiles of the fluctuating radial, poloidal and toroidal magnetic fields have shown good agreement with eigenfunctions of a single helical mode. The edge magnetic fluctuation spectra are somewhat broader than what are expected from internal magnetic field profiles. In spite of these slight discrepancies, the usual measure for the QSH, the spectral index NS lower than 2, still provides a reasonable measure for QSH states in RELAX. The QSH persistence has been improved in RELAX by the reduction of the poloidal resistance of flanges at poloidal gaps, mainly due to the improved axisymmetry of the toroidal magnetic field. QSH persistence more than 30% of the flat-topped current phase has been realized with current density lower than in other RFP, and probability of spontaneous QSH is 12.8 ± 7.3% which is higher than high-aspect-ratio RFP. It suggests the advantage of low-aspect-ratio configuration in attaining to the QSH. Comparison with recent experiments using active resonant perturbation may suggest the importance of further reduction of field errors to improve the quality of QSH.
2012
Istituto gas ionizzati - IGI - Sede Padova
quasi-single-helicity (QSH)
reversed field pinch
low aspect ratio RFP
magnetic fluctuation
internal magnetic field
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/218401
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? ND
social impact