structure of a gasoline spray from a GDI injector for automotive applications based on polycapillary optics is reported. Table-top experiment using a microfocus Cu K? Xray source for radiography and tomography has been used in combination with a polycapillary halflens and a CCD detector. The GDI injector is inserted in a high-pressure rotating device actuated with angular steps ?? = 1° at the injection pressure of 8.0 MPa. The sinogram reconstruction of the jets by slices permits a 360° spray access to the fuel downstream the nozzle tip. A spatial distribution of the fuel is reported along the direction of six jets giving a measure of the droplet concentration in a circle of 16 mm2 below the nozzle tip at atmospheric backpressure and ambient temperature
Tomography of a GDI spray by polyCO based x-ray technique
LMarchitto;
2013
Abstract
structure of a gasoline spray from a GDI injector for automotive applications based on polycapillary optics is reported. Table-top experiment using a microfocus Cu K? Xray source for radiography and tomography has been used in combination with a polycapillary halflens and a CCD detector. The GDI injector is inserted in a high-pressure rotating device actuated with angular steps ?? = 1° at the injection pressure of 8.0 MPa. The sinogram reconstruction of the jets by slices permits a 360° spray access to the fuel downstream the nozzle tip. A spatial distribution of the fuel is reported along the direction of six jets giving a measure of the droplet concentration in a circle of 16 mm2 below the nozzle tip at atmospheric backpressure and ambient temperatureI documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.