We propose a method for the measurements of the O-17/O-16 isotope amount ratio in water, based upon the use of a pair of offset-frequency locked extended-cavity diode lasers at 1.39 mu m. This method enables one to acquire absorption spectra with an extremely high fidelity, exploiting the highly accurate, absolute, and repeatable frequency axis. One of the two lasers, namely the so-called slave laser, is continuously scanned across a pair of (H2O)-O-16 and (H2O)-O-17 lines at 7183.5 cm(-1) and it interacts with a water vapor sample inside a multiple reflections cell, thus producing absorption spectra with a signal-to-noise ratio of the order of 4000 for a detection bandwidth of 1 kHz. The determination of the isotope amount ratio is performed through a careful analysis of the acquired spectra, by using semiclassical line profiles. In this respect, the influence of the choice of the line shape model is investigated. The experimental reproducibility of the spectrometer has been carefully assessed by means of an Allan variance analysis. Finally, the application of the Kalman filtering technique has shown that a precision of 0.6% can be achieved, from repeated spectral acquisitions over a time span of 6000 s.

Amount-ratio determinations of water isotopologues by dual-laser absorption spectrometry

Galzerano;Gianluca;Laporta;Paolo;
2012

Abstract

We propose a method for the measurements of the O-17/O-16 isotope amount ratio in water, based upon the use of a pair of offset-frequency locked extended-cavity diode lasers at 1.39 mu m. This method enables one to acquire absorption spectra with an extremely high fidelity, exploiting the highly accurate, absolute, and repeatable frequency axis. One of the two lasers, namely the so-called slave laser, is continuously scanned across a pair of (H2O)-O-16 and (H2O)-O-17 lines at 7183.5 cm(-1) and it interacts with a water vapor sample inside a multiple reflections cell, thus producing absorption spectra with a signal-to-noise ratio of the order of 4000 for a detection bandwidth of 1 kHz. The determination of the isotope amount ratio is performed through a careful analysis of the acquired spectra, by using semiclassical line profiles. In this respect, the influence of the choice of the line shape model is investigated. The experimental reproducibility of the spectrometer has been carefully assessed by means of an Allan variance analysis. Finally, the application of the Kalman filtering technique has shown that a precision of 0.6% can be achieved, from repeated spectral acquisitions over a time span of 6000 s.
2012
Istituto di fotonica e nanotecnologie - IFN
QUANTUM-CASCADE-LASER
OXYGEN-ISOTOPE RATIOS
MU-M
FREQUENCY STABILIZATION
CARBON-DIOXIDE
DIODE-LASERS
SPECTROSCOPY
LINES
CALIBRATION
PRESSURE
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/221136
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 11
social impact