PURPOSE. To investigate the biomechanics of the anterior human corneal stroma using atomic force microscopy (AFM). METHODS. AFM measurements were performed in liquid on the anterior stroma of human corneas, after gently removing the epithelium, using an atomic force microscope in the force spectroscopy mode. Rectangular silicon cantilevers with tip radius of 10 nm and spring elastic constants of 25- and 33-N/m were used. Each specimen was subjected to increasing loads up to a maximum of 2.7 N with scan speeds ranging between 3- and 95-m/s. The anterior stromal hysteresis during the extension-retraction cycle was quantified as a function of the application load and scan rate. The elastic modulus of the anterior stroma was determined by fitting force curve data to the Sneddon model. RESULTS. The anterior stroma exhibited significant viscoelasticity at micrometric level: asymmetry in the curve loading-unloading response with considerable hysteresis dependent both on the application load and scan rate (P 0.01). The mean elastic modulus ranged between 1.14 and 2.63 MPa and was constant over the range of indentation depths between 1.0 and 2.7 m in the stroma. CONCLUSIONS. At microscale level, the mechanical response of the most anterior stroma is complex and nonlinear. The microstructure (fibers' packing, number of cross-links, water content) and the combination of elastic (collagen fibers) and viscous (matrix) components of the tissue influence the type of viscoelastic response. Efforts in modeling the biomechanics of human corneal tissue at micrometric level are needed.

Biomechanics of the Anterior Human Corneal Tissue Investigated with Atomic Force Microscopy

Lombardo G;De Santo MP;
2012

Abstract

PURPOSE. To investigate the biomechanics of the anterior human corneal stroma using atomic force microscopy (AFM). METHODS. AFM measurements were performed in liquid on the anterior stroma of human corneas, after gently removing the epithelium, using an atomic force microscope in the force spectroscopy mode. Rectangular silicon cantilevers with tip radius of 10 nm and spring elastic constants of 25- and 33-N/m were used. Each specimen was subjected to increasing loads up to a maximum of 2.7 N with scan speeds ranging between 3- and 95-m/s. The anterior stromal hysteresis during the extension-retraction cycle was quantified as a function of the application load and scan rate. The elastic modulus of the anterior stroma was determined by fitting force curve data to the Sneddon model. RESULTS. The anterior stroma exhibited significant viscoelasticity at micrometric level: asymmetry in the curve loading-unloading response with considerable hysteresis dependent both on the application load and scan rate (P 0.01). The mean elastic modulus ranged between 1.14 and 2.63 MPa and was constant over the range of indentation depths between 1.0 and 2.7 m in the stroma. CONCLUSIONS. At microscale level, the mechanical response of the most anterior stroma is complex and nonlinear. The microstructure (fibers' packing, number of cross-links, water content) and the combination of elastic (collagen fibers) and viscous (matrix) components of the tissue influence the type of viscoelastic response. Efforts in modeling the biomechanics of human corneal tissue at micrometric level are needed.
2012
Istituto per i Processi Chimico-Fisici - IPCF
Cornea Biomechanics
AFM
indentation
visco-elastic response
File in questo prodotto:
File Dimensione Formato  
prod_192540-doc_109477.pdf

non disponibili

Descrizione: Cornea Biomechanics Characterization
Tipologia: Versione Editoriale (PDF)
Dimensione 1.13 MB
Formato Adobe PDF
1.13 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/222046
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 58
social impact