We describe a tunable diode laser spectrometer for the in situ simultaneous detection of the nitric acid and the water vapour by means of high resolution absorption spectroscopy on rovibronic lines, using a single laser emitting in the mid-infrared (5.8 microns) and a multipass cell. The instrument was designed to be installed on a high altitude aircraft, as a part of a composite payload for atmospheric aerosol studies. The instrument design criteria are discussed and the expected performances are compared with results of laboratory and field operation. Due to the high chemical activity of HNO3, that makes diffcult to use a reference cell, a fast sweep detection of direct absorption was used for the measurement. An absorption sensitivity of about 2x10-4 was achieved with an integration time of 2.5 s, corresponding to a concentration of about 4 ppb of HNO3 in the cell and 0.1 ppb in the external aerosol. The data acquisition and processing techniques, based on the full molecular lineshape fitting are also shown and discussed, including some examples of the data acquired during the scientific fights.

An Airborne Diode Laser Spectrometer for the Simultaneous Measurement of H2O and HNO3 Content of Stratospheric Cirrus Clouds

Toci G;
2002

Abstract

We describe a tunable diode laser spectrometer for the in situ simultaneous detection of the nitric acid and the water vapour by means of high resolution absorption spectroscopy on rovibronic lines, using a single laser emitting in the mid-infrared (5.8 microns) and a multipass cell. The instrument was designed to be installed on a high altitude aircraft, as a part of a composite payload for atmospheric aerosol studies. The instrument design criteria are discussed and the expected performances are compared with results of laboratory and field operation. Due to the high chemical activity of HNO3, that makes diffcult to use a reference cell, a fast sweep detection of direct absorption was used for the measurement. An absorption sensitivity of about 2x10-4 was achieved with an integration time of 2.5 s, corresponding to a concentration of about 4 ppb of HNO3 in the cell and 0.1 ppb in the external aerosol. The data acquisition and processing techniques, based on the full molecular lineshape fitting are also shown and discussed, including some examples of the data acquired during the scientific fights.
2002
Istituto di Fisica Applicata - IFAC
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/22322
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact