Investigations on surface properties of poly(dimethylsiloxane) (PDMS) are justified by its large application ranges especially as coating polymer in fluidic devices. At a micrometer scale, the liquid dynamics is strongly modified by interactions with a solid surface. A crucial parameter for this process is microchannel wettability that can be tuned by acting on surface chemistry and topography. In literature, a number of multi-step, time and cost consuming chemical and physical procedures are reported. Here we selectively modify both wetting and mechanical properties by a single step treatment. Changes of PDMS surface were investigated by X-ray photoelectron spectroscopy and atomic force microscopy and the effects of interface properties on the liquid displacement inside a microfluidic system were evaluated. The negative capillary pressure obtained tailoring the PDMS wettability is believed to be promising to accurately control sample leakage inside integrated lab-on-chip by acting on the liquid confinement and thus to reduce the sample volume, liquid drying as well as cross-contamination during the operation. © 2012 Elsevier B.V. All rights reserved.

The influence of polydimethylsiloxane curing ratio on capillary pressure in microfluidic devices

Viola Ilenia;Zacheo Antonella;Arima Valentina;Cortese Barbara;Taurino Antonietta;Rinaldi R;Gigli Giuseppe
2012

Abstract

Investigations on surface properties of poly(dimethylsiloxane) (PDMS) are justified by its large application ranges especially as coating polymer in fluidic devices. At a micrometer scale, the liquid dynamics is strongly modified by interactions with a solid surface. A crucial parameter for this process is microchannel wettability that can be tuned by acting on surface chemistry and topography. In literature, a number of multi-step, time and cost consuming chemical and physical procedures are reported. Here we selectively modify both wetting and mechanical properties by a single step treatment. Changes of PDMS surface were investigated by X-ray photoelectron spectroscopy and atomic force microscopy and the effects of interface properties on the liquid displacement inside a microfluidic system were evaluated. The negative capillary pressure obtained tailoring the PDMS wettability is believed to be promising to accurately control sample leakage inside integrated lab-on-chip by acting on the liquid confinement and thus to reduce the sample volume, liquid drying as well as cross-contamination during the operation. © 2012 Elsevier B.V. All rights reserved.
2012
Istituto di Nanotecnologia - NANOTEC
Istituto per la Microelettronica e Microsistemi - IMM
Istituto di Tecnologie Avanzate per l'Energia - ITAE
Istituto Nanoscienze - NANO
Capillary pressure
Lab-on-chip
Microfluidics
PDMS
Wettability
XPS
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.