We described a two-step process to fabricate the heparinized polypropylene (PP) film using cyanuric chloride (CC) as a trifunctional reagent and poly (ethylene glycol) methacrylate (PEGMA) as a spacer. The modified PP films were characterized by attenuated total reflectance FT-IR and X-ray photoelectron spectroscopy; the content of PEGMA and heparin were determined by gravimetric method and a toluidine blue assay, respectively. For the PP-g-PEGMA films, it was found that small size protein BSA tended to adsorb on the surface of low molecular weight monomer grafted PP, whereas big spindle-shaped fibrinogen tended to adsorb on the surface of high molecular weight monomer grafted PP. We gave a definition of anti-protein adsorptive factor r with two model proteins, albumin and fibrinogen. The results by platelet adhesion and plasma recalcification time (PRT) experiments indicated that the factor r could be used to quantitatively evaluate the anticoagulant tendency of PP-g-PEGMA modified films. For the PP-g-PEGMA-g-heparin modified films, the surface was proved to have a high bioactivity by the adsorption of AT III assay and very low platelet adhesion. It indicated that immobilization of heparin on the PP film with PEGMA as a spacer was an effective way to improve the hemocompatibility of PP.

Fabrication of PP-g-PEGMA-g-heparin and its hemocompatibility: From protein adsorption to anticoagulant tendency

Stagnaro P
2012

Abstract

We described a two-step process to fabricate the heparinized polypropylene (PP) film using cyanuric chloride (CC) as a trifunctional reagent and poly (ethylene glycol) methacrylate (PEGMA) as a spacer. The modified PP films were characterized by attenuated total reflectance FT-IR and X-ray photoelectron spectroscopy; the content of PEGMA and heparin were determined by gravimetric method and a toluidine blue assay, respectively. For the PP-g-PEGMA films, it was found that small size protein BSA tended to adsorb on the surface of low molecular weight monomer grafted PP, whereas big spindle-shaped fibrinogen tended to adsorb on the surface of high molecular weight monomer grafted PP. We gave a definition of anti-protein adsorptive factor r with two model proteins, albumin and fibrinogen. The results by platelet adhesion and plasma recalcification time (PRT) experiments indicated that the factor r could be used to quantitatively evaluate the anticoagulant tendency of PP-g-PEGMA modified films. For the PP-g-PEGMA-g-heparin modified films, the surface was proved to have a high bioactivity by the adsorption of AT III assay and very low platelet adhesion. It indicated that immobilization of heparin on the PP film with PEGMA as a spacer was an effective way to improve the hemocompatibility of PP.
2012
Istituto per lo Studio delle Macromolecole - ISMAC - Sede Milano
Inglese
258
15
5841
5849
http://ac.els-cdn.com/S0169433212003583/1-s2.0-S0169433212003583-main.pdf?_tid=7ed7224c-24e7-11e2-aa74-00000aab0f01&acdnat=1351858925_eed0e6337c887afa963880b9597af08f
Sì, ma tipo non specificato
Hemocompatibility
Heparin
PEG
Polypropylene
Protein adsorption
6
info:eu-repo/semantics/article
262
Jin, J; Jiang, W; Shi, Q; Zhao, J; Yin, Jh; Stagnaro, P
01 Contributo su Rivista::01.01 Articolo in rivista
restricted
File in questo prodotto:
File Dimensione Formato  
prod_189635-doc_40631.pdf

solo utenti autorizzati

Descrizione: Fabrication of PP-g-PEGMA-g-heparin and its hemocompatibility: From protein adsorption to anticoagulant tendency
Dimensione 1.57 MB
Formato Adobe PDF
1.57 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/225336
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 53
  • ???jsp.display-item.citation.isi??? 48
social impact