We report on optical-fiber cavity ring-down spectroscopy (CRDS) in the liquid phase using a laser emitting at telecommunication wavelengths. A fiber-ring cavity, comprising a short evanescent-wave coupler for radiation-matter interaction, is used as a sensor while its resonance modes are frequency locked to the laser. Exploiting the intrinsic sensitivity and noise immunity of the CRDS technique, we show that liquid absorption can be detected down to a level that is nearly a factor of 20 above the shot noise limit. We provide a thorough comparison between the experimental results and various noise contributions and address different expressions that can be used to calculate the shot noise equivalent absorbance. As a proof of principle, polyamine detection in aqueous solutions is carried out demonstrating a minimum detectable absorbance of 1.8*10<sup>-7</sup>Hz<sup>-1/2</sup>, which, to our knowledge, is the best sensitivity limit reported to date for evanescent-wave sensors.

High-sensitivity ring-down evanescent-wave sensing in fiber resonators.

Avino S;Giorgini A;Malara P;Zullo R;De Natale P;Gagliardi G
2014

Abstract

We report on optical-fiber cavity ring-down spectroscopy (CRDS) in the liquid phase using a laser emitting at telecommunication wavelengths. A fiber-ring cavity, comprising a short evanescent-wave coupler for radiation-matter interaction, is used as a sensor while its resonance modes are frequency locked to the laser. Exploiting the intrinsic sensitivity and noise immunity of the CRDS technique, we show that liquid absorption can be detected down to a level that is nearly a factor of 20 above the shot noise limit. We provide a thorough comparison between the experimental results and various noise contributions and address different expressions that can be used to calculate the shot noise equivalent absorbance. As a proof of principle, polyamine detection in aqueous solutions is carried out demonstrating a minimum detectable absorbance of 1.8*10-7Hz-1/2, which, to our knowledge, is the best sensitivity limit reported to date for evanescent-wave sensors.
2014
Istituto Nazionale di Ottica - INO
Istituto Nazionale di Ottica - INO
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/225653
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? ND
social impact