Closed-loop devices delivering medical treatments in an automatic fashion clearly require a thorough preliminary phase according to which the proposed control law is tested and validated as realistically as possible, before arranging in vivo experiments in a clinical setting. The present note develops a virtual environment aiming to validate a recently proposed model-based glucose control law on a solid simulation framework. From a theoretical viewpoint, the artificial pancreas has been designed by suitably exploiting a minimal set of delay differential equations modeling the glucose-insulin regulatory system; on the other hand, the validation platform makes use of a different, multi-compartmental model to build up a population of virtual patients. Simulations are carried out by properly addressing the available technological limits and the unavoidable uncertainties in real-time continuous glucose sensors as well as possible malfunctioning on the insulin delivery devices. The results show the robustness of the proposed control law that turns out to be efficient and extremely safe on a heterogenous population of virtual patients.

Model-based control of plasma glycemia: Tests on populations of virtual patients

Palumbo Pasquale;Panunzi Simona;
2014

Abstract

Closed-loop devices delivering medical treatments in an automatic fashion clearly require a thorough preliminary phase according to which the proposed control law is tested and validated as realistically as possible, before arranging in vivo experiments in a clinical setting. The present note develops a virtual environment aiming to validate a recently proposed model-based glucose control law on a solid simulation framework. From a theoretical viewpoint, the artificial pancreas has been designed by suitably exploiting a minimal set of delay differential equations modeling the glucose-insulin regulatory system; on the other hand, the validation platform makes use of a different, multi-compartmental model to build up a population of virtual patients. Simulations are carried out by properly addressing the available technological limits and the unavoidable uncertainties in real-time continuous glucose sensors as well as possible malfunctioning on the insulin delivery devices. The results show the robustness of the proposed control law that turns out to be efficient and extremely safe on a heterogenous population of virtual patients.
2014
Istituto di Analisi dei Sistemi ed Informatica ''Antonio Ruberti'' - IASI
Artificial pancreas
Feedback control law
Time-delay systems
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/227075
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 32
  • ???jsp.display-item.citation.isi??? ND
social impact