The NIO1 (Negative Ion Optimization phase 1) project consists of a multiaperture negative ion source mounted on a 60 kV accelerating column; up to 9 beamlets (15 mA H- each one) arranged in 3 x 3 matrix with 14 mm spacing can be extracted. The moderate size and the modular concept make some relative rotation of the source magnetic filter and the electrodes possible, so that the effect of crossed and aligned field can be easily compared. Other goals of source experimental program are emittance (and beam profile) measurement at several distances (for simulation code validation), testing of diagnostic components and of radiofrequency coupling. A full set of construction drawing was completed; also the Fast Emittance Scanner (FES) and its vacuum chambers were built (four mounting positions are reserved to FES). Some low power rf matching boxes were developed for a test plasma, approximately half the source size. A cesium oven compatible with NIO1 is being also developed; by using some industrial standard 100 W heaters (with a proper driver) a careful control of temperature is planned.

Status of NIO1 construction

G Serianni;V Antoni;M Recchia;
2011

Abstract

The NIO1 (Negative Ion Optimization phase 1) project consists of a multiaperture negative ion source mounted on a 60 kV accelerating column; up to 9 beamlets (15 mA H- each one) arranged in 3 x 3 matrix with 14 mm spacing can be extracted. The moderate size and the modular concept make some relative rotation of the source magnetic filter and the electrodes possible, so that the effect of crossed and aligned field can be easily compared. Other goals of source experimental program are emittance (and beam profile) measurement at several distances (for simulation code validation), testing of diagnostic components and of radiofrequency coupling. A full set of construction drawing was completed; also the Fast Emittance Scanner (FES) and its vacuum chambers were built (four mounting positions are reserved to FES). Some low power rf matching boxes were developed for a test plasma, approximately half the source size. A cesium oven compatible with NIO1 is being also developed; by using some industrial standard 100 W heaters (with a proper driver) a careful control of temperature is planned.
2011
Istituto gas ionizzati - IGI - Sede Padova
Inglese
SECOND INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES
2nd International Symposium on Negative Ions, Beams and Sources (NIBS)
640
649
10
978-0-7354-0955-2
http://proceedings.aip.org/resource/2/apcpcs/1390/1/640_1
American Institute of Physics
Melville [NY]
STATI UNITI D'AMERICA
No
NOV 16-19, 2010
Takayama, JAPAN
AIP conference proceedings (Online) Attiva dal: 1970 Editore: American Institute of Physics, - New York Paese di pubblicazione: Stati Uniti d'America Lingua: inglese Issn: 1551-7616 Titolo chiave: AIP conference proceedings (Online) Titolo proprio: AIP conference proceedings (Online) Titolo abbreviato: AIP conf. proc. (Online) Titoli alternativi: American Institute of Physics conference proceedings (Online) A.I.P. conference proceedings (Online)
3
none
M. Cavenago; E. Fagotti; M. Poggia; G. Serianni; V. Antoni; M.Bigi; F. Fellin; E. Gazza; M. Recchia; P. Veltri; S. Petrenko; T. Kulevoy
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
   EU Fusion for ITER Applications
   EUFORIA
   FP7
   211804
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/229135
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact