The Acceleration Grid Power Supply of the ITER Neutral Beam Injector is designed to deliver up to 200 kV to each of the five stages of the electrostatic accelerator, producing a total voltage up to -1 MV with respect to ground. In the present design, the output voltages of the dc generators are independently controlled by five closed control loops. The output voltage measurements are obtained from the difference between the grid potential measurements, referred to local ground. Therefore, the control precision for each stage is affected by the amplification of the measurement errors. Thus, an alternative control scheme, based on a single closed control loop and regulator, has been considered. In this paper, the performance of the two control methods in terms of systematic errors, dynamic performance and sensitivity to load variations are evaluated and compared.

CONTROL STRATEGY FOR THE ACCELERATION VOLTAGE OF THE ITER NEUTRAL BEAM INJECTOR

Vanni Toigo
2011

Abstract

The Acceleration Grid Power Supply of the ITER Neutral Beam Injector is designed to deliver up to 200 kV to each of the five stages of the electrostatic accelerator, producing a total voltage up to -1 MV with respect to ground. In the present design, the output voltages of the dc generators are independently controlled by five closed control loops. The output voltage measurements are obtained from the difference between the grid potential measurements, referred to local ground. Therefore, the control precision for each stage is affected by the amplification of the measurement errors. Thus, an alternative control scheme, based on a single closed control loop and regulator, has been considered. In this paper, the performance of the two control methods in terms of systematic errors, dynamic performance and sensitivity to load variations are evaluated and compared.
2011
Istituto gas ionizzati - IGI - Sede Padova
Inglese
2011 IEEE/NPSS 24TH SYMPOSIUM ON FUSION ENGINEERING (SOFE)
24th IEEE/NPSS Symposium on Fusion Engineering (SOFE)
6052343
5
978-1-4577-0669-1
IEEE, Institute of electrical and electronics engineers
New York
STATI UNITI D'AMERICA
June 26-30, 2011
Chicago, IL, USA
ITER
neutral beam injector
power supplies
voltage control
Article number: 6052343; E-ISBN: 978-1-4577-0667-7; Print ISBN: 978-1-4577-0669-1; INSPEC Accession Number: 12340557
3
none
Ferro, Alberto; Zanotto, Loris; Toigo, Vanni
273
info:eu-repo/semantics/conferenceObject
04 Contributo in convegno::04.01 Contributo in Atti di convegno
   EU Fusion for ITER Applications
   EUFORIA
   FP7
   211804
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/229166
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact