The acceleration grid power supply of the ITER neutral beam injector is designed to deliver up to 200 kV to each of the five stages of the electrostatic accelerator, producing a total voltage up to -1 MV with respect to ground. In the present design, the output voltages of the dc generators are independently controlled by five closed control loops. The output voltage measurements are obtained from the difference between the grid potential measurements, referred to local ground. Therefore, the control accuracy for each stage is affected by the amplification of the measurement errors. Thus, an alternative control scheme, based on a single closed control loop and regulator, has been considered. In this paper, the performance of the two control methods in terms of systematic errors, dynamic performance, and sensitivity to load variations is evaluated and compared.

Control Strategy for the Acceleration Voltage of the ITER Neutral Beam Injector

Vanni Toigo
2012

Abstract

The acceleration grid power supply of the ITER neutral beam injector is designed to deliver up to 200 kV to each of the five stages of the electrostatic accelerator, producing a total voltage up to -1 MV with respect to ground. In the present design, the output voltages of the dc generators are independently controlled by five closed control loops. The output voltage measurements are obtained from the difference between the grid potential measurements, referred to local ground. Therefore, the control accuracy for each stage is affected by the amplification of the measurement errors. Thus, an alternative control scheme, based on a single closed control loop and regulator, has been considered. In this paper, the performance of the two control methods in terms of systematic errors, dynamic performance, and sensitivity to load variations is evaluated and compared.
2012
Istituto gas ionizzati - IGI - Sede Padova
Inglese
40
3
564
569
6
http://biblioproxy.cnr.it:2093/xpls/icp.jsp?arnumber=6088019
Sì, ma tipo non specificato
ITER
neutral beam injector
power supplies
voltage control
La rivista è pubblicata anche online con ISSN 1939-9375.
3
info:eu-repo/semantics/article
262
Ferro, Alberto; Zanotto, Loris; Toigo, Vanni
01 Contributo su Rivista::01.01 Articolo in rivista
none
   EU Fusion for ITER Applications
   EUFORIA
   FP7
   211804
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/230535
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 12
social impact