The central electron temperature and density of the ITER plasma may be determined by Thomson scattering. A LIDAR topology is proposed in order to minimize the port access required of the ITER vacuum vessel. By using a LIDAR technique, a profile of the electron temperature and density can be determined with a resolution of about 7 cm in the central region of the plasma by using a short pulse laser (similar to 300 ps). Requirements for advanced plasma control indicate that such measurements should be taken at a rate of 100 Hz during a plasma shot. The limited collection cone angle possible on the ITER reactor implies the use of a high pulse energy laser (similar to 5 J at 1 mu m). The combination of very high average power and peak power required represents a serious challenge for current laser technology. Schemes able to provide this level of laser performance will be presented along with efficient and cost effective methods of maximizing the collected light while minimizing the collection of background light by the use of an axicon element.

The ITER Thomson scattering core LIDAR diagnostic

R Pasqualotto;
2012

Abstract

The central electron temperature and density of the ITER plasma may be determined by Thomson scattering. A LIDAR topology is proposed in order to minimize the port access required of the ITER vacuum vessel. By using a LIDAR technique, a profile of the electron temperature and density can be determined with a resolution of about 7 cm in the central region of the plasma by using a short pulse laser (similar to 300 ps). Requirements for advanced plasma control indicate that such measurements should be taken at a rate of 100 Hz during a plasma shot. The limited collection cone angle possible on the ITER reactor implies the use of a high pulse energy laser (similar to 5 J at 1 mu m). The combination of very high average power and peak power required represents a serious challenge for current laser technology. Schemes able to provide this level of laser performance will be presented along with efficient and cost effective methods of maximizing the collected light while minimizing the collection of background light by the use of an axicon element.
2012
Istituto gas ionizzati - IGI - Sede Padova
Inglese
7
10
http://iopscience.iop.org/1748-0221/7/03/C03043/pdf/1748-0221_7_03_C03043.pdf
Sì, ma tipo non specificato
Optics
Plasma diagnostics - interferometry spectroscopy and imaging
Plasma diagnostics probes
This work was funded partly by the RCUK Energy Programme under Grant EP/I501045 and the European Communities under the contract of Association between EURATOM and CCFE. This work was carried out within the framework of the European Fusion Development Agreement. "Funding under Association Contract FU07-CT-2007-00053". / IOP Publishing Ltd and Sissa Medialab srl / Article Number: C03043.
1
info:eu-repo/semantics/article
262
G.A. Naylor; R. Scannell; M. Beurskens; M.J. Walsh; I. Pastor; A.J.H. Donné; B. Snijders; W. Biel; B. Meszaros; L. Giudicotti; R. Pasqualotto; L. Maro...espandi
01 Contributo su Rivista::01.01 Articolo in rivista
none
   EU Fusion for ITER Applications
   EUFORIA
   FP7
   211804
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/230577
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 10
social impact