The increasing importance of providing reliable polarimetric measurements in real time, for both machine protection and plasma control, has motivated the development of a quick version of the calibration algorithms for JET polarimeter. This new code, which interprets the calibration procedure performed before each shot, is based on a physical equivalent model of the diagnostic optical path and is valid for any operational regime of JET. It provides results before the plasma breakdown, and, with its estimates of the optical paths parameters, the polarimetric measurements have an accuracy more than sufficient for real-time purposes. New approximate equations have been validated in order to obtain the line integrated density from the newly calibrated horizontal chords, so that also these polarimetric measurements can also be used for density feedback and machine protection. The availability of reliable polarimetric measurements in real time opens new perspectives also to the determination of the plasma boundary, the magnetic equilibrium, and their use in advanced feedback control schemes.

New Approximations and Calibration Methods to Provide Routine Real-Time Polarimetry on JET

Andrea Murari;
2012

Abstract

The increasing importance of providing reliable polarimetric measurements in real time, for both machine protection and plasma control, has motivated the development of a quick version of the calibration algorithms for JET polarimeter. This new code, which interprets the calibration procedure performed before each shot, is based on a physical equivalent model of the diagnostic optical path and is valid for any operational regime of JET. It provides results before the plasma breakdown, and, with its estimates of the optical paths parameters, the polarimetric measurements have an accuracy more than sufficient for real-time purposes. New approximate equations have been validated in order to obtain the line integrated density from the newly calibrated horizontal chords, so that also these polarimetric measurements can also be used for density feedback and machine protection. The availability of reliable polarimetric measurements in real time opens new perspectives also to the determination of the plasma boundary, the magnetic equilibrium, and their use in advanced feedback control schemes.
2012
Istituto gas ionizzati - IGI - Sede Padova
Inglese
40
4
1149
1161
13
http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6156793
Sì, ma tipo non specificato
Line integrated density
polarimetry
real-time
"Funding under Association Contract FU07-CT-2007-00053". / Article number: 6156793; / La rivista è pubblicata anche online con ISSN 1939-9375.
1
info:eu-repo/semantics/article
262
Michela Gelfusa; Andrea Murari; Pasquale Gaudio; Alexandru Boboc; Didler Mazon; Fabio Avino; Ivan Lupelli; F. P. Orsitto; O. Tudisco; JETEFDA Contribu...espandi
01 Contributo su Rivista::01.01 Articolo in rivista
none
   EU Fusion for ITER Applications
   EUFORIA
   FP7
   211804
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/231231
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact