A facility will be built in Padova (Italy) to develop, commission, and optimize the neutral beam injection system for ITER. The full scale prototype negative ion radio frequency source SPIDER, featuring up to 100 kV acceleration voltage, includes a full set of diagnostics, required for safe operation and to measure and optimize the beam performance. Among them, beam emission spectroscopy (BES) will be used to measure the line integrated beam uniformity, divergence, and neutralization losses inside the accelerator (stripping losses). In the absence of the neutralization stage, SPIDER beam is mainly composed by H- or D- particles, according to the source filling gas. The capability of a spectroscopic diagnostic of an H- (D-) beam relies on the interaction of the beam particles with the background gas particles. The BES diagnostic will be able to acquire the H-alpha (D-alpha) spectrum from up to 40 lines of sight. The system is capable to resolve stripping losses down to 2 keV and to measure beam divergence with an accuracy of about 10%. The design of this diagnostic is reported, with discussion of the layout and its components, together with simulations of the expected performance.

Design of a beam emission spectroscopy diagnostic for negative ions radio frequency source SPIDER

R Pasqualotto
2012

Abstract

A facility will be built in Padova (Italy) to develop, commission, and optimize the neutral beam injection system for ITER. The full scale prototype negative ion radio frequency source SPIDER, featuring up to 100 kV acceleration voltage, includes a full set of diagnostics, required for safe operation and to measure and optimize the beam performance. Among them, beam emission spectroscopy (BES) will be used to measure the line integrated beam uniformity, divergence, and neutralization losses inside the accelerator (stripping losses). In the absence of the neutralization stage, SPIDER beam is mainly composed by H- or D- particles, according to the source filling gas. The capability of a spectroscopic diagnostic of an H- (D-) beam relies on the interaction of the beam particles with the background gas particles. The BES diagnostic will be able to acquire the H-alpha (D-alpha) spectrum from up to 40 lines of sight. The system is capable to resolve stripping losses down to 2 keV and to measure beam divergence with an accuracy of about 10%. The design of this diagnostic is reported, with discussion of the layout and its components, together with simulations of the expected performance.
2012
Istituto gas ionizzati - IGI - Sede Padova
Inglese
83
4
8
http://rsi.aip.org/resource/1/rsinak/v83/i4/p04311
Sì, ma tipo non specificato
-
This work was set up in collaboration and financial support of Fusion for Energy. / Article Number: 043117; La rivista è pubblicata anche online con ISSN 1089-7623.
2
info:eu-repo/semantics/article
262
Zaniol, B; Pasqualotto, R; Barbisan, M
01 Contributo su Rivista::01.01 Articolo in rivista
none
   EU Fusion for ITER Applications
   EUFORIA
   FP7
   211804
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/231235
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 24
social impact