The dynamics of a three-catalytic-reactor network, where an exothermic irreversible reaction occurs, is studied. The network is operated by periodically switching feed and discharge positions (with the period being 1). We analyzed the effect of two different switch strategies and observed different spatio-temporal patterns. Such differences result from the different spatio-temporal symmetry that is induced by the switch strategies. Their effect on the stability is studied by comparing the stability range of T-periodic regimes as the switch time is varied for different values of the feed temperature. This analysis is conducted by a numerical continuation technique based on the spatio-temporal symmetry of the forced system. For low (ambient) feed temperature, the stability ranges of a diabatic reactor conform to criteria previously proposed for adiabatic reactors [Sheintuch, M; Nekhamkina, O. AIChE J. 2005, 51, 224]. We observe that these criteria cannot be applied at higher feed temperatures, as a consequence of the external heat losses. One of the examined switch strategies is used to determine a significant widening of the operability conditions.

Effect of the switch strategy on the stability of reactor networks

Russo L;
2007

Abstract

The dynamics of a three-catalytic-reactor network, where an exothermic irreversible reaction occurs, is studied. The network is operated by periodically switching feed and discharge positions (with the period being 1). We analyzed the effect of two different switch strategies and observed different spatio-temporal patterns. Such differences result from the different spatio-temporal symmetry that is induced by the switch strategies. Their effect on the stability is studied by comparing the stability range of T-periodic regimes as the switch time is varied for different values of the feed temperature. This analysis is conducted by a numerical continuation technique based on the spatio-temporal symmetry of the forced system. For low (ambient) feed temperature, the stability ranges of a diabatic reactor conform to criteria previously proposed for adiabatic reactors [Sheintuch, M; Nekhamkina, O. AIChE J. 2005, 51, 224]. We observe that these criteria cannot be applied at higher feed temperatures, as a consequence of the external heat losses. One of the examined switch strategies is used to determine a significant widening of the operability conditions.
2007
Istituto di Ricerche sulla Combustione - IRC - Sede Napoli
PERIODIC-FLOW REVERSAL; FIXED-BED REACTORS; CATALYTIC COMBUSTION;
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/231992
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 16
social impact