The clinical success of second-generation metal-on-metal hip replacement and the good tribological performance of alumina ceramic revived an interest in hip articulation as a solution to reduce wear. This study was aimed at characterizing the wear behaviour of new hybrid ceramic-on-metal bearings. In particular, this study investigated the wear behaviour of ceramic-on-metal hip components (three different diameters configurations: 28, 32 and 36 mm), not specifically proposed to be coupled, in order to compare them with ceramic-on-ceramic, which is considered to be the gold standard for wear resistance. For this purpose, the weight loss over a standard wear simulation was monitored. Moreover, scanning electronic microscope observations were used to verify if any carbides removal, for the metallic components, triggered wears debris production promoting abrasive third-body wear. After five million cycles, our results showed significantly greater wear-in ceramic-on-metal compared with ceramic-on-ceramic, and significant greater wear for the 32-mm diameter compared with the 36-mm one. Our findings showed an increase in wear for the proposed hybrid specimens with respect to that of the ceramic-on-ceramic ones confirming that even in the case of ceramic-on-metal bearings, mixing and matching could not prove effective wear behaviour, not even comparable with that of the ceramic-on-ceramic gold standard. Wear patterns and roundness tolerances certainly discourage the coupling of components not specifically intended to be coupled. Unsuitable geometrical conformity could, in fact, result in a poor dynamic behaviour and lead to clinical failure.

Mixing and matching in ceramic-on-metal hip arthroplasty: an in-vitro hip simulator study .

Squarzoni S;
2009

Abstract

The clinical success of second-generation metal-on-metal hip replacement and the good tribological performance of alumina ceramic revived an interest in hip articulation as a solution to reduce wear. This study was aimed at characterizing the wear behaviour of new hybrid ceramic-on-metal bearings. In particular, this study investigated the wear behaviour of ceramic-on-metal hip components (three different diameters configurations: 28, 32 and 36 mm), not specifically proposed to be coupled, in order to compare them with ceramic-on-ceramic, which is considered to be the gold standard for wear resistance. For this purpose, the weight loss over a standard wear simulation was monitored. Moreover, scanning electronic microscope observations were used to verify if any carbides removal, for the metallic components, triggered wears debris production promoting abrasive third-body wear. After five million cycles, our results showed significantly greater wear-in ceramic-on-metal compared with ceramic-on-ceramic, and significant greater wear for the 32-mm diameter compared with the 36-mm one. Our findings showed an increase in wear for the proposed hybrid specimens with respect to that of the ceramic-on-ceramic ones confirming that even in the case of ceramic-on-metal bearings, mixing and matching could not prove effective wear behaviour, not even comparable with that of the ceramic-on-ceramic gold standard. Wear patterns and roundness tolerances certainly discourage the coupling of components not specifically intended to be coupled. Unsuitable geometrical conformity could, in fact, result in a poor dynamic behaviour and lead to clinical failure.
2009
Istituto di Genetica Molecolare "Luigi Luca Cavalli Sforza"
Ceramic on metal
Roundness measurements
Hip wear rate
COC
COM
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/23242
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact