Recently, Hamamatsu has developed a new dynode structure in a position-sensitive photomultiplier tube (PSPMT) based on metal channel technology, producing a very focused charge distribution. Hamamatsu R5900-C8 is the first metal channel dynode PSPMT with a crossed wire anode. The outline dimension is 28 × 28 × 20 mm3 with an active area of 21 × 22 mm2 and four wire anodes (4X + 4Y). A weighted summing device was realised to calculate the charge distribution centroid where each anode was directly connected to a preamplifier and amplifier. Tests of position linearity, energy response and spatial resolution were carried out coupling the PSPMT to an NaI(Tl) planar crystal and to a YAP:Ce scintillation array. To test the influence of charge spread on position linearity, the photocathode was irradiated by a light spot with 1 mm of aperture size. Position non-linearity resulted when a scintillating array with 1 × 1 mm2 pixel size was coupled to PSPMT. On the contrary, increasing the spread of charge distribution by a planar scintillation crystal, a good linearity response was obtained. Impressive spatial resolution values were obtained from the YAP:Ce scintillating array. They ranged between 0.5 and 0.2 mm irradiating the crystals by 57Co and 137Cs source, respectively.

New generation position-sensitive PMT for nuclear medicine imaging

A Soluri;
1997

Abstract

Recently, Hamamatsu has developed a new dynode structure in a position-sensitive photomultiplier tube (PSPMT) based on metal channel technology, producing a very focused charge distribution. Hamamatsu R5900-C8 is the first metal channel dynode PSPMT with a crossed wire anode. The outline dimension is 28 × 28 × 20 mm3 with an active area of 21 × 22 mm2 and four wire anodes (4X + 4Y). A weighted summing device was realised to calculate the charge distribution centroid where each anode was directly connected to a preamplifier and amplifier. Tests of position linearity, energy response and spatial resolution were carried out coupling the PSPMT to an NaI(Tl) planar crystal and to a YAP:Ce scintillation array. To test the influence of charge spread on position linearity, the photocathode was irradiated by a light spot with 1 mm of aperture size. Position non-linearity resulted when a scintillating array with 1 × 1 mm2 pixel size was coupled to PSPMT. On the contrary, increasing the spread of charge distribution by a planar scintillation crystal, a good linearity response was obtained. Impressive spatial resolution values were obtained from the YAP:Ce scintillating array. They ranged between 0.5 and 0.2 mm irradiating the crystals by 57Co and 137Cs source, respectively.
1997
INGEGNERIA BIOMEDICA
Inglese
392
319
323
4
http://biblioproxy.cnr.it:2065/10.1016/S0168-9002(97)00255-6
Sì, ma tipo non specificato
PSPMT
medical imaging scintillation crystal
9
info:eu-repo/semantics/article
262
Pani, R; Pergola, A; Pellegrini, R; Soluri, A; De Vincentis, G; Filippi, S; Di Domenico, G; Del Guerra, A; Scopinaro, F
01 Contributo su Rivista::01.01 Articolo in rivista
none
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/235609
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact