Capillary electrophoresis has been used for the separation of venlafaxine and two of its impurities deriving from the synthesis process. The electrophoretic experiments were performed using background electrolytes at different pHs in the 2.5-9.2 range in order to study the effective mobilities and resolution of the three examined compounds. The optimum experimental conditions for the baseline resolution of the three analytes was found at pH 6.5. Very good repeatability for both migration time and corrected peak areas was achieved. The calibration curve was studied for venlafaxine (concentration range 26-224 micrograms/mL), and the plot of the peak area ratio (sample/internal standard [IS]) versus venlafaxine concentration was linear with a correlation coefficient of 0.9991. The effect of different cyclodextrins (CDs), namely, gamma-cyclodextrin (gamma-CD), hydroxypropyl-beta-CD (HP-beta-CD), and alpha-cyclodextrin (alpha-CD), on effective mobility and enantiomeric resolution (R) of venlafaxine (Wy45030) and its impurities (imp1 and imp2) was studied at different pHs, and the best results were obtained at pH 9.2. Venlafaxine was baseline resolved in its enantiomers using gamma-CD or HP-beta-CD, while imp1 (Wy45494) was baseline resolved using alpha-CD.

Analysis of venlafaxine by capillary zone electrophoresis

FANALI S;
1997

Abstract

Capillary electrophoresis has been used for the separation of venlafaxine and two of its impurities deriving from the synthesis process. The electrophoretic experiments were performed using background electrolytes at different pHs in the 2.5-9.2 range in order to study the effective mobilities and resolution of the three examined compounds. The optimum experimental conditions for the baseline resolution of the three analytes was found at pH 6.5. Very good repeatability for both migration time and corrected peak areas was achieved. The calibration curve was studied for venlafaxine (concentration range 26-224 micrograms/mL), and the plot of the peak area ratio (sample/internal standard [IS]) versus venlafaxine concentration was linear with a correlation coefficient of 0.9991. The effect of different cyclodextrins (CDs), namely, gamma-cyclodextrin (gamma-CD), hydroxypropyl-beta-CD (HP-beta-CD), and alpha-cyclodextrin (alpha-CD), on effective mobility and enantiomeric resolution (R) of venlafaxine (Wy45030) and its impurities (imp1 and imp2) was studied at different pHs, and the best results were obtained at pH 9.2. Venlafaxine was baseline resolved in its enantiomers using gamma-CD or HP-beta-CD, while imp1 (Wy45494) was baseline resolved using alpha-CD.
1997
Istituto per i Sistemi Biologici - ISB (ex IMC)
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/236017
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact