In our companion paper we presented a model to describe photon migration through a diffusing slab. The model, developed for a homogeneous slab, is based on the diffusion approximation and is able to take into account reflection at the boundaries resulting from the refractive index mismatch. In this paper the predictions of the model are compared with solutions of the radiative transfer equation obtained by Monte Carlo simulations in order to determine the applicability limits of the approximated theory in different physical conditions. A fitting procedure, carried out with the optical properties as fitting parameters, is used to check the application of the model to the inverse problem. The results show that significant errors can be made if the effect of the refractive index mismatch is not properly taken into account. Errors are more important when measurements of transmittance are used. The effects of using a receiver with a limited angular field of view and the angular distribution of the radiation that emerges from the slab have also been investigated.

Photon migration through a turbid slab described by a model based on diffusion approximation. 2. Comparison with Monte Carlo results

Contini D;
1997

Abstract

In our companion paper we presented a model to describe photon migration through a diffusing slab. The model, developed for a homogeneous slab, is based on the diffusion approximation and is able to take into account reflection at the boundaries resulting from the refractive index mismatch. In this paper the predictions of the model are compared with solutions of the radiative transfer equation obtained by Monte Carlo simulations in order to determine the applicability limits of the approximated theory in different physical conditions. A fitting procedure, carried out with the optical properties as fitting parameters, is used to check the application of the model to the inverse problem. The results show that significant errors can be made if the effect of the refractive index mismatch is not properly taken into account. Errors are more important when measurements of transmittance are used. The effects of using a receiver with a limited angular field of view and the angular distribution of the radiation that emerges from the slab have also been investigated.
1997
Diffusion equation
Monte Carlo
optical properties
diffuse transmittance
diffuse reflectance
tissue optics
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/236387
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 90
social impact