In this study, a rapid separation of eleven polyphenols and three methylxanthines was obtained by means of nano-liquid chromatography (nano-LC), employing a 100 ?m I.D. capillary column packed with C18 core-shell particles (2.7 ?m) for 10 cm. All compounds were baseline resolved with a step gradient elution in less than 15 min. The developed analytical method was validated and the resulting RSD% for intra-day and inter-day repeatability, related to retention time, retention factor and peak area, were below 5.1 and 5.7%. LOD and LOQ values corresponded to 0.300 and 0.625 ?g/mL, while linearity range assessed gave R2 no lower than 0.990. Then, the method was used to determine studied compounds in tea extracts. Further, the nano-LC system was coupled with a mass spectrometer to confirm the components present in real samples. Finally the results were compared with those obtained using a capillary column (100 ?m I.D. × 10 cm) packed with C18 sub-2 ?m particles, applying the same nano-LC experimental conditions

Analysis of polyphenols and methylxantines in tea samples by means of nano-liquid chromatography utilizing capillary columns packed with core-shell particles

A Rocco;Z Aturki;S Fanali
2012

Abstract

In this study, a rapid separation of eleven polyphenols and three methylxanthines was obtained by means of nano-liquid chromatography (nano-LC), employing a 100 ?m I.D. capillary column packed with C18 core-shell particles (2.7 ?m) for 10 cm. All compounds were baseline resolved with a step gradient elution in less than 15 min. The developed analytical method was validated and the resulting RSD% for intra-day and inter-day repeatability, related to retention time, retention factor and peak area, were below 5.1 and 5.7%. LOD and LOQ values corresponded to 0.300 and 0.625 ?g/mL, while linearity range assessed gave R2 no lower than 0.990. Then, the method was used to determine studied compounds in tea extracts. Further, the nano-LC system was coupled with a mass spectrometer to confirm the components present in real samples. Finally the results were compared with those obtained using a capillary column (100 ?m I.D. × 10 cm) packed with C18 sub-2 ?m particles, applying the same nano-LC experimental conditions
2012
Istituto per i Sistemi Biologici - ISB (ex IMC)
nano-LC
polyphenols
tea
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/236886
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 36
  • ???jsp.display-item.citation.isi??? ND