BACKGROUND: The perfusion index (PI), derived from the pulse oximetry signal, has been shown to be an accurate predictor for identifying high illness severity in neonates. The plethysmographic variability index (PVI) is a measure of the dynamic change in PI occurring during a complete respiratory cycle. OBJECTIVES: The aim of this study was to establish the reference range of PVI in spontaneously breathing term newborns. METHODS: PI and PVI values were assessed in 242 term newborns during the first day of life. RESULTS: The median PVI value on the first day of life was 20% [95% confidence interval (CI) for the mean 19-20%; inter-quartile range 15 (95% CI 15-16) - 24 (95% CI 23-24)]. The 10th and 90th percentile cutoff values were 12% (95% CI 11-12) and 28% (95% CI 27-29), respectively, with the 97.5th percentile of 35% (95% CI 34-38). PVI was also significantly influenced by the behavioral status of the newborn, and was positively correlated with PI and pulse rate, while it was inversely correlated with oxygen saturation (p < 0.0001). CONCLUSIONS: Our findings suggest: (1) evaluation of PVI values is an easily applicable, noninvasive procedure for monitoring early postnatal respiratory changes in newborns, and (2) the feasibility of a noninvasive pulse-oximeter postnatal screening for early identification of adverse neonatal cardiorespiratory outcomes.

First day of life reference values for pleth variability index in spontaneously breathing term newborns.

Dipaola Lucia;
2012

Abstract

BACKGROUND: The perfusion index (PI), derived from the pulse oximetry signal, has been shown to be an accurate predictor for identifying high illness severity in neonates. The plethysmographic variability index (PVI) is a measure of the dynamic change in PI occurring during a complete respiratory cycle. OBJECTIVES: The aim of this study was to establish the reference range of PVI in spontaneously breathing term newborns. METHODS: PI and PVI values were assessed in 242 term newborns during the first day of life. RESULTS: The median PVI value on the first day of life was 20% [95% confidence interval (CI) for the mean 19-20%; inter-quartile range 15 (95% CI 15-16) - 24 (95% CI 23-24)]. The 10th and 90th percentile cutoff values were 12% (95% CI 11-12) and 28% (95% CI 27-29), respectively, with the 97.5th percentile of 35% (95% CI 34-38). PVI was also significantly influenced by the behavioral status of the newborn, and was positively correlated with PI and pulse rate, while it was inversely correlated with oxygen saturation (p < 0.0001). CONCLUSIONS: Our findings suggest: (1) evaluation of PVI values is an easily applicable, noninvasive procedure for monitoring early postnatal respiratory changes in newborns, and (2) the feasibility of a noninvasive pulse-oximeter postnatal screening for early identification of adverse neonatal cardiorespiratory outcomes.
2012
Istituto di Fisiologia Clinica - IFC
Pleth variability index
Perfusion index
Screening
neonates
File in questo prodotto:
File Dimensione Formato  
prod_185077-doc_32864.pdf

solo utenti autorizzati

Descrizione: First day of life reference values for pleth variability index in spontaneously breathing term newborns.
Dimensione 94.11 kB
Formato Adobe PDF
94.11 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/239937
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? ND
social impact