Capillary electrophoresis (CE) was used for the simultaneous chiral determination of venlafaxine (Vx), a new antidepressant drug and its main active metabolite, O-desmethyl venlafaxine (ODV). Among the charged cyclodextrins (CD) tested, phosphated ?-CD was the most appropriate. Resolution of Vx and ODV was obtained with 50 mM phosphate buffer (pH 2.5) containing 20 mg/ml of phosphated ?-CD. After optimisation of the method (including robustness), validation was carried out. Vx and ODV concentrations, as well as the enantiomeric ratio, were investigated in clinical samples. Chiral determination of Vx and ODV was performed after a simple liquid-liquid extraction (LLE). In the tested concentration range (25-500 ng/ml), coefficients of correlation were superior to 0.996. Within-day and between-day accuracy and precision were determined at three different concentrations for each enantiomer. Analyses of clinical samples (n=16) exhibited non-racemic ratios for Vx and ODV, which suggests a stereoselective metabolism in humans. Copyright (C) 2000 Elsevier Science B.V.

Simultaneous stereoselective analysis of venlafaxine and O-desmethylvenlafaxine enantiomers in clinical samples by capillary electrophoresis using charged cyclodextrins

FANALI S;
2000

Abstract

Capillary electrophoresis (CE) was used for the simultaneous chiral determination of venlafaxine (Vx), a new antidepressant drug and its main active metabolite, O-desmethyl venlafaxine (ODV). Among the charged cyclodextrins (CD) tested, phosphated ?-CD was the most appropriate. Resolution of Vx and ODV was obtained with 50 mM phosphate buffer (pH 2.5) containing 20 mg/ml of phosphated ?-CD. After optimisation of the method (including robustness), validation was carried out. Vx and ODV concentrations, as well as the enantiomeric ratio, were investigated in clinical samples. Chiral determination of Vx and ODV was performed after a simple liquid-liquid extraction (LLE). In the tested concentration range (25-500 ng/ml), coefficients of correlation were superior to 0.996. Within-day and between-day accuracy and precision were determined at three different concentrations for each enantiomer. Analyses of clinical samples (n=16) exhibited non-racemic ratios for Vx and ODV, which suggests a stereoselective metabolism in humans. Copyright (C) 2000 Elsevier Science B.V.
2000
Istituto per i Sistemi Biologici - ISB (ex IMC)
cyclodextrins
capillary zone electrophoresis
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/241705
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact