Non-invasive detection of diseases, based on urinary proteomics, is becoming an increasingly important area of research, especially in the area of chronic kidney disease (CKD). Different platforms have been used in independent studies, mostly capillary-electrophoresis coupled ESI-MS (CE-MS), liquid chromatography coupled mass spectrometry, and matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). We have compared the performance of CE-MS with MALDI-MS in detecting CKD, based on a cohort of 137 urine samples (62 cases and 75 controls). Data cross-talk between the two platforms was established for the comparison of detected biomarkers. The results demonstrate superior performance of the CE-MS approach in terms of peptide resolution and obtained disease prediction accuracy rates. However, the data also demonstrate the ability of the MALDI-MS approach to separate CKD patients from controls, at slightly reduced accuracy, but expected reduced cost and time. As a consequence, a practical approach can be foreseen where MALDI-MS is employed as an inexpensive, fast, and robust screening tool to detect probable CKD. In a second step, high resolution CE-MS could be used in those patients only that scored negative for CKD in the MALDI-MS analysis, reducing costs and time of such a program.

A comparison between MALDI-MS and CE-MS data for biomarker assessment in chronic kidney diseases

Seraglia R;
2012

Abstract

Non-invasive detection of diseases, based on urinary proteomics, is becoming an increasingly important area of research, especially in the area of chronic kidney disease (CKD). Different platforms have been used in independent studies, mostly capillary-electrophoresis coupled ESI-MS (CE-MS), liquid chromatography coupled mass spectrometry, and matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). We have compared the performance of CE-MS with MALDI-MS in detecting CKD, based on a cohort of 137 urine samples (62 cases and 75 controls). Data cross-talk between the two platforms was established for the comparison of detected biomarkers. The results demonstrate superior performance of the CE-MS approach in terms of peptide resolution and obtained disease prediction accuracy rates. However, the data also demonstrate the ability of the MALDI-MS approach to separate CKD patients from controls, at slightly reduced accuracy, but expected reduced cost and time. As a consequence, a practical approach can be foreseen where MALDI-MS is employed as an inexpensive, fast, and robust screening tool to detect probable CKD. In a second step, high resolution CE-MS could be used in those patients only that scored negative for CKD in the MALDI-MS analysis, reducing costs and time of such a program.
2012
Istituto di Chimica della Materia Condensata e di Tecnologie per l'Energia - ICMATE
Istituto di Scienze e Tecnologie Molecolari - ISTM - Sede Milano
Biomarker
Capillary electrophoresis
CE-MS
Chronic kidney disease
MALDI-MS
Urine
File in questo prodotto:
File Dimensione Formato  
prod_195457-doc_89834.pdf

solo utenti autorizzati

Descrizione: A comparison between MALDI-MS and CE-MS data for biomarker assessment in chronic kidney diseases
Dimensione 848.45 kB
Formato Adobe PDF
848.45 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/242843
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 60
  • ???jsp.display-item.citation.isi??? 53
social impact