In this article an experimental setup designed to assist in the characterization of complex solute transport problems in porous media is described. Glass beads representing the medium are confined in a 2-D transparent Perspex box and a water flow transports a fluorescent dye. Under suitable illumination, the dye emits visible light which is collected by a CCD camera. The image acquired by this non-invasive optical technique is processed to estimate the 2-dimensional distribution of tracer concentrations by using an appropriate calibration curve that links fluorescent intensity and solute concentration. Details about the dye choice and discussion about photobleaching are reported. An analysis of the experimental error on the concentration profile is also presented. A few recent results of a study on contaminant plume within a homogenous porous matrix constituted by glass beads having mean diameter of 1 mm or 2 mm shows the performance of constructed model.

Assessment of quantitative imaging of contaminant distributions in porous media

G Bracco;
2008

Abstract

In this article an experimental setup designed to assist in the characterization of complex solute transport problems in porous media is described. Glass beads representing the medium are confined in a 2-D transparent Perspex box and a water flow transports a fluorescent dye. Under suitable illumination, the dye emits visible light which is collected by a CCD camera. The image acquired by this non-invasive optical technique is processed to estimate the 2-dimensional distribution of tracer concentrations by using an appropriate calibration curve that links fluorescent intensity and solute concentration. Details about the dye choice and discussion about photobleaching are reported. An analysis of the experimental error on the concentration profile is also presented. A few recent results of a study on contaminant plume within a homogenous porous matrix constituted by glass beads having mean diameter of 1 mm or 2 mm shows the performance of constructed model.
2008
Istituto dei Materiali per l'Elettronica ed il Magnetismo - IMEM
CONTAMINANTS; POROUS MEDIA; FLUORESCENCE TECHNIQUE; SOLUTE TRANSPORT
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/243545
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 20
social impact