Capillary zone electrophoresis was successfully applied to the enantiomeric resolution of racemic tramadol and its six phase I metabolites using carboxymethylated ?-cyclodextrin (CMB) added to the background electrolyte (BGE). Baseline resolution of tramadol and its metabolites was obtained in less than 30 min using a 50 mM phosphate buffer (pH 2.5) containing 5 mM of CMB. Chiral determinations of tramadol and its main three metabolites, O-demethyltramadol (M1), N-demethyltramadol (M2) and O-demethyl-N-demethyltramadol (M5), were performed in urine after a simple double liquid-liquid extraction of 200 ?l of biological material. In the tested concentration range (0.5-20 ?g/ml, except for M2: 0.5-10 ?g/ml) coefficients of correlation superior than 0.994 were obtained. Within-day variation determined on three different concentrations for each enantiomers showed accuracies ranging from 95.4% to 103.2%. The relative standard deviation (RSD) of these assays was determined to be less than 10.0%. Day-to-day variation presented accuracies ranging from 96.3% to 106.5% with a RSD less than 9.0%. After oral administration of 100 mg of tramadol hydrochloride to an healthy volunteer, the urinary excretion was monitored during 30 h. About 15% of the dose was excreted as unchanged tramadol. The enantiomeric ratios of all the excreted analytes, T, M1, M2 and M5, were found to be very different to 1.0, showing that a stereoselective metabolism of tramadol clearly occurred.

Simultaneous stereoselective analysis by capillary electrophoresis of tramadol enantiomers and their main phase I metabolites in urine

DESIDERIO C;FANALI S
1999

Abstract

Capillary zone electrophoresis was successfully applied to the enantiomeric resolution of racemic tramadol and its six phase I metabolites using carboxymethylated ?-cyclodextrin (CMB) added to the background electrolyte (BGE). Baseline resolution of tramadol and its metabolites was obtained in less than 30 min using a 50 mM phosphate buffer (pH 2.5) containing 5 mM of CMB. Chiral determinations of tramadol and its main three metabolites, O-demethyltramadol (M1), N-demethyltramadol (M2) and O-demethyl-N-demethyltramadol (M5), were performed in urine after a simple double liquid-liquid extraction of 200 ?l of biological material. In the tested concentration range (0.5-20 ?g/ml, except for M2: 0.5-10 ?g/ml) coefficients of correlation superior than 0.994 were obtained. Within-day variation determined on three different concentrations for each enantiomers showed accuracies ranging from 95.4% to 103.2%. The relative standard deviation (RSD) of these assays was determined to be less than 10.0%. Day-to-day variation presented accuracies ranging from 96.3% to 106.5% with a RSD less than 9.0%. After oral administration of 100 mg of tramadol hydrochloride to an healthy volunteer, the urinary excretion was monitored during 30 h. About 15% of the dose was excreted as unchanged tramadol. The enantiomeric ratios of all the excreted analytes, T, M1, M2 and M5, were found to be very different to 1.0, showing that a stereoselective metabolism of tramadol clearly occurred.
1999
Istituto per i Sistemi Biologici - ISB (ex IMC)
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/244015
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact