The Source for Production of Ion of Deuterium Extracted from Rf plasma (SPIDER) test facility is under construction in Padova to optimise the operation of the beam source of ITER neutral beam injectors. The SPIDER beam will be characterised by the instrumented calorimeter STRIKE, whose main components are one-directional carbon-fibre-carbon-composite tiles. A small-scale version of the entire system has been employed in the BAvarian Test MAchine for Negative ions (BATMAN) testbed by arranging two prototype tiles in the vertical direction. The paper presents a description of the mini-STRIKE system and of the data analysis procedures, as well as some results concerning the BATMAN beam under varying operating conditions.

First negative ion beam measurement by the Short-Time Retractable Instrumented Kalorimeter Experiment (STRIKE)

Serianni G;Muraro A;Bonomo F;Pasqualotto R;
2014

Abstract

The Source for Production of Ion of Deuterium Extracted from Rf plasma (SPIDER) test facility is under construction in Padova to optimise the operation of the beam source of ITER neutral beam injectors. The SPIDER beam will be characterised by the instrumented calorimeter STRIKE, whose main components are one-directional carbon-fibre-carbon-composite tiles. A small-scale version of the entire system has been employed in the BAvarian Test MAchine for Negative ions (BATMAN) testbed by arranging two prototype tiles in the vertical direction. The paper presents a description of the mini-STRIKE system and of the data analysis procedures, as well as some results concerning the BATMAN beam under varying operating conditions.
2014
Istituto di fisica del plasma - IFP - Sede Milano
Istituto gas ionizzati - IGI - Sede Padova
Inglese
85
2
02A736
3
http://scitation.aip.org/content/aip/journal/rsi/85/2/10.1063/1.4861391
Sì, ma tipo non specificato
SPIDER
Serianni Gianluigi: reprint Author. / Work set up in collaboration and financial support of F4E. / Article Number: 02A736 / Contributed paper, published as part of the Proceedings of the 15th International Conference on Ion Sources, Chiba, Japan, September 2013. / Review of scientific instruments online Editore: American Institute of Physics Paese di pubblicazione: Stati Uniti d'America Lingua: inglese e-Issn: 1089-7623 Titolo chiave: Review of scientific instruments online Titolo proprio: Review of scientific instruments online Titolo abbreviato: Rev. sci. instrum. online
13
info:eu-repo/semantics/article
262
Serianni, G; De Muri, M; Muraro, A; Veltri, P; Bonomo, F; Chitarin, G; Pasqualotto, R; Pavei, M; Rizzolo, A; Valente, M; Franzen, P; Ruf, B; Schiesko,...espandi
01 Contributo su Rivista::01.01 Articolo in rivista
restricted
   EU Fusion for ITER Applications
   EUFORIA
   FP7
   211804
File in questo prodotto:
File Dimensione Formato  
prod_281118-doc_79934.pdf

solo utenti autorizzati

Descrizione: First negative ion beam measurement by the Short-Time Retractable
Tipologia: Versione Editoriale (PDF)
Dimensione 832.13 kB
Formato Adobe PDF
832.13 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/244778
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 20
social impact