Some overtone absorption lines of water vapor in the region around 12100 cm-1 have been examined by using a diode laser (DL) spectrometer [1]. The employed sources are commercially available double heterostructure AlxGa1-xAs DLs operating in "free-running" mode; still the high resolving power (~107) of the spectrometer permits the detection and the study of the absorption features of the molecules with a precision of less than 0.01 cm-1. Wavelength modulation spectroscopy (WMS) along with the 2nd harmonic detection techniques have been adopted in order to maximize the signal to noise ratio (S/N) and to extract the necessary informations either on the line width and on the line position for each resonance. The fit procedure has been critically analyzed in order to take into account the instrumental effects and the amplitude modulation (AM) always associated to the frequency modulation (FM) of these sources [2]. Collisional broadening and shifting coefficients by three different perturber gases have been measured at room temperature. The results are compared to those obtained by more expensive spectroscopic systems. 1. A. Lucchesini, S. Gozzini, C. Gabbanini, Eur. Phys. J. D, Vol. 8, 223-226 (2000) 2. M. De Rosa, A. Ciucci, D. Pelliccia, C. Gabbanini, S. Gozzini, A. Lucchesini, Opt. Commun., Vol. 147, 55-60 (1997)

Pressure Line Broadening And Shifting of Water Vapor Overtones

A Lucchesini;S Gozzini
2001

Abstract

Some overtone absorption lines of water vapor in the region around 12100 cm-1 have been examined by using a diode laser (DL) spectrometer [1]. The employed sources are commercially available double heterostructure AlxGa1-xAs DLs operating in "free-running" mode; still the high resolving power (~107) of the spectrometer permits the detection and the study of the absorption features of the molecules with a precision of less than 0.01 cm-1. Wavelength modulation spectroscopy (WMS) along with the 2nd harmonic detection techniques have been adopted in order to maximize the signal to noise ratio (S/N) and to extract the necessary informations either on the line width and on the line position for each resonance. The fit procedure has been critically analyzed in order to take into account the instrumental effects and the amplitude modulation (AM) always associated to the frequency modulation (FM) of these sources [2]. Collisional broadening and shifting coefficients by three different perturber gases have been measured at room temperature. The results are compared to those obtained by more expensive spectroscopic systems. 1. A. Lucchesini, S. Gozzini, C. Gabbanini, Eur. Phys. J. D, Vol. 8, 223-226 (2000) 2. M. De Rosa, A. Ciucci, D. Pelliccia, C. Gabbanini, S. Gozzini, A. Lucchesini, Opt. Commun., Vol. 147, 55-60 (1997)
2001
Istituto Nazionale di Ottica - INO - Sede Secondaria di Pisa
1-56396-991-2
molecular physics
water vapor
laser spectroscopy
overtones
laser diode
File in questo prodotto:
File Dimensione Formato  
prod_313410-doc_89977.pdf

solo utenti autorizzati

Descrizione: AIP Conference Proceedings 559 (2001)
Tipologia: Versione Editoriale (PDF)
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 88.65 kB
Formato Adobe PDF
88.65 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/249429
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 0
social impact