The Joint European Torus (JET) tokamak has two light detection and ranging (LIDAR) Thomson scattering systems, one for the core and one dedicated to the edge T-e and n(e) profiles. The LIDAR scheme is unique to JET and is envisaged for use on ITER. The system's spatial resolution is defined by the convolution product of its components: laser pulse duration, detector response time, and digitizer speed. The original multialkali photocathode microchannel plate photomultipliers dictated the response time, resulting in a 12 cm spatial resolution along the line of sight. In the edge LIDAR system, this is improved by aligning the line of sight with the flux surfaces, thus improving the effective spatial resolution to 2 cm depending on the plasma configuration. To meet demands for better edge gradient resolution, an upgrade to higher quantum efficiency detectors was proposed. Four GaAs photocathode detectors have been procured, two of which surpass expectations. These detectors are shown to have a more than two times higher effective quantum efficiency and their response time is at least twice as fast as the multialkali detectors. Combined with a fast digitizer this improves the spatial resolution by a factor of two, down to one centimeter effective, depending on plasma configuration. (C) 2004 American Institute of Physics.

Comparison of Multialkali and GaAs photocathode detectors for Joint European Torus edge light detection and ranging Thomson scattering profiles

2004

Abstract

The Joint European Torus (JET) tokamak has two light detection and ranging (LIDAR) Thomson scattering systems, one for the core and one dedicated to the edge T-e and n(e) profiles. The LIDAR scheme is unique to JET and is envisaged for use on ITER. The system's spatial resolution is defined by the convolution product of its components: laser pulse duration, detector response time, and digitizer speed. The original multialkali photocathode microchannel plate photomultipliers dictated the response time, resulting in a 12 cm spatial resolution along the line of sight. In the edge LIDAR system, this is improved by aligning the line of sight with the flux surfaces, thus improving the effective spatial resolution to 2 cm depending on the plasma configuration. To meet demands for better edge gradient resolution, an upgrade to higher quantum efficiency detectors was proposed. Four GaAs photocathode detectors have been procured, two of which surpass expectations. These detectors are shown to have a more than two times higher effective quantum efficiency and their response time is at least twice as fast as the multialkali detectors. Combined with a fast digitizer this improves the spatial resolution by a factor of two, down to one centimeter effective, depending on plasma configuration. (C) 2004 American Institute of Physics.
2004
Istituto gas ionizzati - IGI - Sede Padova
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/25401
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 11
social impact