Although the Energy Dispersive X-ray Diffraction (EDXD) technique has proved to have several merits in comparison with its conventional Angular Dispersive (ADXD) counterpart, it has the serious drawback that its resolution is intrinsically lower than that of the latter. This makes EDXD unsuitable each time that high-resolution measurements are needed. However, a wide class of samples does not require high resolution since the diffraction peaks they produce are so wide that the further broadening due to the use of EDXD is negligible. Amorphous solids, liquids, semi- crystalline materials, nanocrystalline powders belong to such category. In this case, it is not worth performing sophisticated simulations to calculate the angular transfer function of the diffractometer because a simplified model is sufficient to describe the effect of the angular divergence of the X-ray beam on the peaks broadening. The aim of the present work is to obtain an analytic function that can be used for this purpose, allowing the collimation system to be properly set up.

The effect of the X-ray beam collimation on the resolution

2002

Abstract

Although the Energy Dispersive X-ray Diffraction (EDXD) technique has proved to have several merits in comparison with its conventional Angular Dispersive (ADXD) counterpart, it has the serious drawback that its resolution is intrinsically lower than that of the latter. This makes EDXD unsuitable each time that high-resolution measurements are needed. However, a wide class of samples does not require high resolution since the diffraction peaks they produce are so wide that the further broadening due to the use of EDXD is negligible. Amorphous solids, liquids, semi- crystalline materials, nanocrystalline powders belong to such category. In this case, it is not worth performing sophisticated simulations to calculate the angular transfer function of the diffractometer because a simplified model is sufficient to describe the effect of the angular divergence of the X-ray beam on the peaks broadening. The aim of the present work is to obtain an analytic function that can be used for this purpose, allowing the collimation system to be properly set up.
2002
Istituto di Struttura della Materia - ISM - Sede Roma Tor Vergata
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/25546
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact