In this work we study the impedance behaviour of microelectrodes arrays nanostructured with different patterns by using a dual beam focused ion beam FIB. The devices were first fabricated by embedding a metal tri-layer of Ti/Au/Cr, 250 nm thick, into two ultra-flexible polyimide layers, reaching a final thickness of 8 ?m. Then, different patterns of holes (diameters from 100 to 500 nm) were produced by milling single pixels at a current of ~10 nA at increasing pitch (up to 3000 nm) and at different dwell time (up to 12 ms). The adopted milling parameters (in particular the single pixel milling strategy at rather high current) allow to obtain a nano-pattern onto an electrode area of 150 × 150 ?m in a reasonably short time (from 10 s to 5 min for each electrode). Other patterns were also investigated in which the FIB was scanned uniformly to induce surface roughening. Electrochemical impedance spectroscopy analysis was performed in vitro in a KCl solution 100 mM, by using a potentiostat VersaSTAT 4 by PAR, finding an average impedance reduction of about one order of magnitude respect to the impedance of the flat electrodes. © 2014 Elsevier B.V. All rights reserved.

Ultra-flexible microelectrode array nanostructured by FIB: A possible route to lower the device impedance

Maiolo L;Notargiacomo A;Marrani M;Minotti A;Maita F;Pecora A
2014

Abstract

In this work we study the impedance behaviour of microelectrodes arrays nanostructured with different patterns by using a dual beam focused ion beam FIB. The devices were first fabricated by embedding a metal tri-layer of Ti/Au/Cr, 250 nm thick, into two ultra-flexible polyimide layers, reaching a final thickness of 8 ?m. Then, different patterns of holes (diameters from 100 to 500 nm) were produced by milling single pixels at a current of ~10 nA at increasing pitch (up to 3000 nm) and at different dwell time (up to 12 ms). The adopted milling parameters (in particular the single pixel milling strategy at rather high current) allow to obtain a nano-pattern onto an electrode area of 150 × 150 ?m in a reasonably short time (from 10 s to 5 min for each electrode). Other patterns were also investigated in which the FIB was scanned uniformly to induce surface roughening. Electrochemical impedance spectroscopy analysis was performed in vitro in a KCl solution 100 mM, by using a potentiostat VersaSTAT 4 by PAR, finding an average impedance reduction of about one order of magnitude respect to the impedance of the flat electrodes. © 2014 Elsevier B.V. All rights reserved.
2014
Istituto di fotonica e nanotecnologie - IFN
Istituto per la Microelettronica e Microsistemi - IMM
Electrochemical impedance spectroscopy
Focused ion beam
Nanostructured electrodes
Ultra-flexible microelectrodes arrays
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14243/256218
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
social impact